background image

Additional settings

79

Program release

It is possible to block access to individual programs. Blocked
programs are not available for selection, so for example it can be
ensured that only validated programs are used.

Open the menu as follows:

Button 

    

 

Additional settings

        

  

Release program

Release program

Selection

All

All

All programs are released for use.

Selection

A selection of programs are available for use.

Select an option using the 

 and 

 arrow buttons and confirm your

selection with 

OK

.

The 

Selection

 option displays a list of all programs.

Release program

Universal

Accept

Programs are selected by multiple choice. A box 

 is shown next to

all programs in the list. If a program is released, there is a tick 

 in

the box. An empty box indicates a blocked program.

Programs can be released or blocked using the arrow buttons 

and 

 and by confirming with 

OK

.

To save the selection, select the 

Accept

 option at the end of the list

and confirm with 

OK

.

Содержание PG 8593

Страница 1: ...uctions Laboratory Glassware Washer PG 8593 To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time en CA M Nr 10 284 370 ...

Страница 2: ...2 ...

Страница 3: ...sioning 25 Installation and connection 25 Procedure 25 Opening and closing the door 29 Electronic door locking 29 Opening the door 29 Closing the door 29 Opening the door using the emergency release 30 Water softener 31 Water hardness 31 Setting the water hardness level 32 Filling the salt reservoir 34 Add salt reminder 36 Application technology 37 Wash carts baskets modules and inserts 37 Upper b...

Страница 4: ... fault 59 Cancelling a program manually 59 Settings 60 Delay start 61 Drying 62 DOS venting 63 Filter change 64 Language 64 Date 65 Time of day 67 Volume 70 Additional settings 71 PIN code 73 Entering the PIN code 73 Log book 76 Report 77 Temperature unit 77 Program settings 77 Air cooling 78 Program release 79 Moving a program allocating program selection buttons 80 Dispensing systems 81 DOS vent...

Страница 5: ...ing the spray arms 121 Cleaning the machine 123 Cleaning the control panel 123 Cleaning the door and the door seal 123 Cleaning the wash cabinet 123 Cleaning the front 123 Preventing re soiling 123 Checking wash carts baskets modules and inserts 124 Performance check 125 Changing the HEPA filter 128 Problem solving guide 130 Technical faults and messages 130 Dispensing Dispensing systems 131 132 I...

Страница 6: ... Connecting the water supply 154 Non pressurized gravity feed DI water connection 1 3 8 7 psi 8 5 60 kPa 156 Connecting the water drain 157 Program guide 158 Free memory 158 Free memory 160 Universal 162 Standard 164 Intensive 166 Inorganic 168 Organic 170 Injector Plus 172 Pipettes 174 Plastics 176 Short 178 Oil program 180 Special 93 C 10 182 Demineralized rinse 184 Rinse 184 Drain 184 Technical...

Страница 7: ...escribe Notes Notes contain information that is particularly important to follow They are highlighted in a thick framed box Additional information and comments Additional information and comments are contained in a box with a simple frame Operating steps Operating steps are indicated by a black square bullet point Example Select an option using the arrow buttons and save your choice with OK Displa...

Страница 8: ...gnetic stirring rods stoppers etc Other items such as funnels pipe hose pieces etc Examples of application areas Laboratories in schools colleges and universities Research quality assurance development technology and production Different areas of inorganic organic analytical and physical chemistry Biology microbiology and biotechnology Hospital laboratories Laboratory glassware and laboratory uten...

Страница 9: ...itoring is set at the factory to be active in the Cleaning and Final rinse wash blocks The spray pressure monitoring result is documented together with an optional process documentation Spray arm speed can also be monitored e g for prompt detection of blockages due to misloading or foam in the water circulation system Spray arm speed monitoring can be activated or deactivated via the programmable ...

Страница 10: ...g interrupting or cancelling a program require more detailed knowledge about the machine reprocessing of laboratory glassware and laboratory utensils Alterations or adaptations of the machine e g accessories used or on site conditions require additional specific knowledge of the machine Validation processes assume specialised knowledge of the machine reprocessing of laboratory glassware and utensi...

Страница 11: ...er machine spray arm e Rails for baskets and wash carts f Lower machine spray arm g Data plate h Reservoir for reactivation salt i Filter combination j Toe kick panel with service flap k On the back Second data plate Electrical and plumbing connections Suction lance s for external supply containers Connections for external dispensing modules optional DOS modules l Connection point for wash carts a...

Страница 12: ...utton cancel For canceling a process in the user interface not for canceling programs g Button settings For accessing the system settings menu h Button Start Stop For starting or canceling a program i Button door release For opening the door before or after a program j Button Drying For switching drying on and off k Button OK For selecting or confirming entries in the user interface l PC Optical i...

Страница 13: ...the end of the program the LED will remain lit until a different program is selected OFF No program has been selected from the list or the program settings are being selected Button ON The additional Drying function has been activated for the selected program not available for all programs see Program chart OFF The additional Drying function has been deactivated Button Start Stop ON A program is r...

Страница 14: ... or operation of the machine This machine is intended for indoor use in a stationary location only Risk of injury Please pay attention to the following notes to avoid injury This machine must be commissioned serviced and repaired by a Miele service technician only To ensure compliance with Good Laboratory Practice guidelines a Miele service contract is recommended Unauthorized repairs can pose con...

Страница 15: ...als only Organic solvents or flammable liquid agents must not be used in it This could cause an explosion property damage due to the destruction of rubber and plastic components and the resulting leakage of liquids The water in the cabinet must not be used as drinking water Do not lift the machine by protruding parts such as the control panel or the opened service flap as these could be damaged or...

Страница 16: ...ng washed are suitable for machine processing and are in good condition Plastic items must be thermally stable Nickel plated items and anodised aluminum items can be machine processed using special procedures only Items containing iron and soiling containing residual rust must not be placed in the cabinet Under certain circumstances process chemicals can cause damage to the machine Always follow t...

Страница 17: ...ng results obtained When using process chemicals always follow the instructions of the chemical s manufacturer The process chemicals must only be used for the application it is designed for and in the situation specified to avoid material damage and such dangers as a severe chemical reaction e g an explosive oxyhydrogen gas reaction Always follow the relevant manufacturer s instructions on storage...

Страница 18: ...t be supervised in the vicinity of the machine Do not allow children to play with the machine Among other hazards they could get locked inside it Children must not use the machine Keep children away from process chemicals These can cause burning in the mouth nose and throat if swallowed or inhibit breathing Keep children away from the machine when the door is open There could still be residual pro...

Страница 19: ...erial etc in it and must be decontaminated before disposal For environmental and safety reasons ensure the machine is completely drained of any residual water chemical residues and cleaning chemicals Observe safety regulations and wear protective eyewear and gloves Remove or destroy the door latch to prevent children from locking themselves in Then make appropriate arrangements for its safe dispos...

Страница 20: ...ant button is sufficient to operate the functions The buttons can also be pressed and held for approx 20 seconds Display illustrations All display illustrations shown in these operating instructions are examples which can be different from the actual display screens shown Universal Temperature Duration h 1 30 75 C The control buttons are shown next to the display The and Start Stop buttons are not...

Страница 21: ...ed some basic parameters e g language date time of day etc must first be set To enable this the display automatically changes to the relevant screen Switching off Press the button The time of day can optionally be displayed when the machine is switched off see Settings Time of day Automatic switch off Auto Off function To save energy the machine has an automatic switch off function Auto Off functi...

Страница 22: ...gh the list to the end of the menu Press the button again to continue navigating Parameter values can also be altered in defined increments using the arrow buttons Instructions for this can be found in the relevant sections OK OK button The OK button is used for confirming acknowledging a selection or for saving input The display then moves to the next menu or when entering parameter values to the...

Страница 23: ... path does not need to be followed completely If for example the Settings menu is already displayed you do not need to press the button again In this case simply follow the sequence from Settings onwards Display view When selecting a menu the last menu used is generally pre selected Example Time format 12 h 24 h Extras All available menu options are listed together with a short description Example...

Страница 24: ...ked with a tick Language english GB english USA System messages The symbol denotes system messages These give information such as e g if the level is too low in the supply containers or a reminder for the next service Refill salt System messages are displayed at the start and end of a program and have to be confirmed acknowledged individually with OK or all together at the end of the program by op...

Страница 25: ...ttings menus The settings made during the commissioning process are only adopted after a complete program has been run If the program is interrupted or if no program is started or the machine is switched off the commissioning process must be carried out again Switching on Press the button until the LED on the keypad lights up Select language The commissioning process starts with selecting the lang...

Страница 26: ...ing the date will then appear Date Use the and arrow buttons to set the day month and year and touch OK to save each one Select Clock display The menu for selecting the clock format will then appear Time format 12 h 24 h Use the and arrow buttons to select the format you want and touch OK to save Setting the time of day The menu for setting the time of day will then appear Time of day Use the and ...

Страница 27: ...ite down the water hardness in Water softener Water hardness Select plumbing connections The menu for setting plumbing connections will then appear Unused plumbing connections e g if there is only one connection can be deactivated here Following commissioning the plumbing connections can be reinstated by Miele Service Plumbing connections Cold water Accept The plumbing connection is set via multip...

Страница 28: ... is completed when the following message is displayed Set up successful Confirm the message with OK The machine is now ready for use Universal Temperature Duration h 1 30 75 C After commissioning every program starts with reactivation of the water softener ...

Страница 29: ...ng the temperature in the wash cabinet is less than 70 C and the LED is lit up Press the button to open the door The Comfort door lock opens the door slightly The LED goes out as soon as the door is unlocked The control panel of the machine is also a door handle Grasp the handle underneath the control panel and lower the door to open it Closing the door Ensure that there are no objects or items in...

Страница 30: ...cy release Push the tool supplied in the accessory pack horizontally into the gap between the door and the lid or worktop The right hand edge of the tool must align with the outer right hand edge of the display Press against the unlocking mechanism with the tool until you hear the door unlock The door can now be opened If the machine is switched on the activation of the emergency release will be r...

Страница 31: ...ite Alternatively your local water supplier will be able to tell you the exact degree of hardness in the mains water supply For future servicing it is useful to make a note of the water hardness level so that you can provide the service technician with this information Enter your water hardness level here ______________________________ gr gal The water softener must also be reactivated at regular ...

Страница 32: ...0 70 gr gal gr gal The bottom line of the display shows the possible input range Water hardness input values can be found in the chart on the next page Where the water hardness fluctuates e g between 8 17 gr gal always program the machine to the higher value 17 gr gal in this example Set the water hardness level using the arrow buttons higher and lower Press OK to save the setting ...

Страница 33: ...49 14 250 2 5 14 50 900 9 0 50 15 270 2 7 15 51 920 9 2 51 16 290 2 9 16 52 940 9 4 52 17 310 3 1 17 53 950 9 5 53 18 320 3 2 18 54 970 9 7 54 19 340 3 4 19 55 990 9 9 55 20 360 3 6 20 56 1010 10 1 56 21 380 3 8 21 57 1030 10 3 57 22 400 4 0 22 58 1040 10 4 58 23 410 4 1 23 59 1060 10 6 59 24 430 4 3 24 60 1080 10 8 60 25 450 4 5 25 61 1100 11 0 61 26 470 4 7 26 62 1120 11 2 62 27 490 4 9 27 63 11...

Страница 34: ...ener Inadvertently filling the salt reservoir with cleaning detergent will cause serious damage to the water softener Before filling the salt reservoir make sure that you have picked up the right package of reactivation salt Open the door to an angle of approx 45 This ensures that the salt flows into the reservoir more easily Press the yellow button with the symbol on the salt reservoir in the dir...

Страница 35: ...ter saline solution may run out Clean any excess salt from the area around the reservoir opening and especially from the seal Do not use running water as this can cause the salt reservoir to overflow Close the reservoir Run the Rinse program after refilling salt This will ensure that any traces of salt and saline solution are dissolved and rinsed away Salt and saline solution which has overflowed ...

Страница 36: ...e reservoir as described When the message first appears there may be sufficient salt for a further program depending on the water hardness level set If there is no saline solution left in the water softener a relevant message will appear in the display and the machine will be locked for further use The machine can be used again a few seconds after the salt has been refilled ...

Страница 37: ...or more connection points to the water supply When loading baskets wash carts etc into the machine connect these to the water connection points in the back panel of the wash cabinet The wash carts and baskets are held in place by the wash cabinet door when closed Any free connections in the back panel are closed mechanically Older models of wash carts and baskets Only use older models of wash cart...

Страница 38: ... baskets are not designed to be positioned on a slant one side up one side down Altering the height will alter loading heights for both the upper and lower baskets To adjust the upper basket Remove the upper basket by pulling it out until a resistance is felt and lifting it off the runners Unscrew the roller brackets and the water connector To adjust the upper basket to the upper position Move the...

Страница 39: ...ning is covered Secure the water connector with 4 screws lower position Move the roller brackets on both sides to the top position and secure them firmly Position the stainless steel plate over the openings in the water supply pipe so that the lower opening is covered Secure the stainless steel plate at the bottom with 2 screws Place the water connector in the upper opening of the stainless steel ...

Страница 40: ...em unrestricted Deep sided items should be placed at an angle to make sure water runs off them freely Tall narrow hollow items should be placed in the centre of the baskets or wash carts if possible to ensure better water coverage Take apart any items which can be dismantled according to the manufacturer s instructions and process the individual parts separately from each other Lightweight items s...

Страница 41: ...ic acid or corrosive iron materials must not be placed in the cabinet Scoop nutrient media Agar out of petri dishes Shake out any blood residues and remove any clots If necessary rinse the wash load briefly with water to avoid introducing coarse soiling into the machine Remove all stoppers corks labels sealing wax residue etc Small items such as stoppers and taps should be secured in suitable bask...

Страница 42: ...insing fittings securely connected Are the baskets and modules or wash carts correctly connected to the water supply and are the water connectors undamaged Are all chemical containers sufficiently filled The following must be checked at the end of every program Carry out a visual check of the load for cleanliness Check that all hollow items are still securely located on their injector nozzles Any ...

Страница 43: ...tomed flasks measuring cylinders and pipettes require injector wash carts or baskets with special injector modules The injector wash carts and modules come with their own operating instructions When loading please note Place petri dishes or similar items in the appropriate insert with the dirty side facing towards the middle Place pipettes with the pointed end facing downwards Quarter segment inse...

Страница 44: ...s between processing chemicals and soiling Heavy foaming during a program affects cleaning and rinsing results Foam escaping from the wash cabinet can cause damage to the machine Cleaning processes cannot be regulated where there has been a build up of foam Establish the cause of the foam and rectify it Check the process used regularly to monitor foaming levels See also the information on Process ...

Страница 45: ...ied and approved by Miele in this machine The instructions and recommendations of the process chemicals must be observed Carry out a regular visual check of any accessible elastomers and plastics for damage Hydrogen peroxide can release large amounts of oxygen Use only certified processes The wash temperature must be lower than 70 C when using hydrogen peroxide Please contact Miele Service for adv...

Страница 46: ...n the machine Oil wax aromatic and unsaturated hydrocarbons emollients cosmetics hygiene and care products such as creams analytical applications filling Depending on usage wipe the lower door seal on the machine periodically with a lint free cloth or sponge Clean the wash cabinet and accessories without a load using the Inorganic program Process the load using the Oil program program where this i...

Страница 47: ...nd soiling Problem How to resolve it Natural oils and fats can be emulsified with alkaline process chemicals This can lead to a heavy build up of foam Use the Oil program Use a special program that dispenses emulsifiers pH neutral in the pre rinse Depending on application use de foaming agents that do not contain silicone oils Soiling containing high protein levels such as blood can cause a heavy ...

Страница 48: ... s safety data sheets must be observed Wear protective goggles and gloves Contact Miele for information about suitable process chemicals Highly viscous thick process chemicals can affect the dispenser monitoring and lead to inaccurate data In this instance please contact Miele Professional Service for advice Dispensing systems The machine is equipped with a number of internal dispensing systems fo...

Страница 49: ... for dispensing hoses Before fitting the DOS module compare the connection data voltage and frequency on the data plate with that on the data plate of your machine If the data does not match the module could sustain damage If in any doubt consult an electrician Connect the module to the machine s power supply To connect the dispensing hose release the hose clip on a free connector and remove the s...

Страница 50: ...m vented for this to occur In the Inorganic program neutralizing agent is dispensed additionally for an acidic pre wash Refilling neutralizing agent Place the neutralizing agent container red marking on the open cabinet door or on a surface which is robust and easy to clean Unscrew and remove the suction lance Place the suction lance on the open cabinet door Replace the empty container with a full...

Страница 51: ...cator When the fill level is low in the DOS 3 supply container for neutralizing agent you are reminded to refill it Refill DOS Confirm the message shown with OK and Refill the neutralising agent as described If it has run out the machine will be locked for further use It will be ready for use again when the supply container has been replaced Dispensing neutralizing agent For adjusting dispensing c...

Страница 52: ...dispensed from an external canister Place the liquid cleaning detergent container blue marking on the open cabinet door or on a surface which is robust and easy to clean Unscrew and remove the suction lance Place the suction lance on the open cabinet door Replace the empty container with a full one Push the suction lance into the opening of the container and screw it on tightly Observe the colour ...

Страница 53: ... is low in the DOS 1 supply container for liquid cleaning detergent you are reminded to replenish it Refill DOS Confirm the message shown with OK and refill the liquid cleaning detergent as described If the liquid cleaning detergent has run out the machine will be locked for further use It will be ready for use again when the supply container has been replaced Dispensing liquid cleaning detergent ...

Страница 54: ... The programs and their areas of application are described in the Program overview at the end of these operating instructions Starting a program Close the door When the door is closed the LED in the button will light up Press the Start Stop button The LED in the Start Stop button will light up constantly and the LED in the button will go out Starting a program using delay start The start of a prog...

Страница 55: ...sing the arrow buttons higher and lower and save your entry with OK The start time is now saved and can be changed as described at any time up to activation of delay start Activating delay start Delay start is activated with the Start Stop button Universal Temperature Switch on at 12 30 75 C The selected program with the start time set is shown in the display If the automatic switch off after func...

Страница 56: ...uration will be longer However the drying duration is not calculated in the program time left shown in the display It will be displayed during the drying phase only Activating and deactivating drying Select a program Press the button before the program start If the drying duration Drying time is set as changeable Time changeable in the program settings the time set can be altered Otherwise the dry...

Страница 57: ...se either to deactivate the drying function or to reset the drying duration as described above Drying Deactivate Set the time Set the time You can alter the drying duration with this option Deactivate Drying is deactivated Select an option using the arrow buttons and and confirm this with OK ...

Страница 58: ...onductivity only for machine version with conductivity meter Bottom line Time left in hours under an hour in minutes End of program A program is usually finished when the following parameters and messages are shown in the display Top line Program name Middle line Continuously alternating between Parameter met not met Cycle number Conductivity in final wash block only for machine version with condu...

Страница 59: ...ually A program which is already running should only be cancelled if strictly necessary e g if the wash load is moving about significantly Press and hold the Start Stop button until the display changes to the following view Program cancellation No Yes Select Yes using the and arrow buttons The program is cancelled when the OK button is pressed Entry of a PIN code may also be required see Further s...

Страница 60: ...em Factory settings are indicated by a tick You will find an explanation of how to change settings after the overview Settings Delay start No Yes Drying No Yes Priming DOS system DOS_ Filter change HEPA filter Reset counter No Yes Language deutsch english GB Date Date format DD MM YY MM DD YY Set Time of day Set Display On On for 60 seconds Do not display Time format 12 h 24 h Volume Keypad tone B...

Страница 61: ...start to be available for use Open the menu as follows Button Settings Delay start Delay start Yes No No Delay start is deactivated Yes Delay start is activated and can be used for all programs Select an option using the and arrow buttons Press OK to save the setting ...

Страница 62: ...iltered air into the wash cabinet for active drying of the load The heated air is exhausted via the steam condenser and can be cooled down if necessary see Further settings Air cooling Open the menu as follows Button Settings Drying Drying Yes No No The drying function is automatically deactivated for all programs Yes The drying function is activated for all programs The program duration is length...

Страница 63: ... is sufficiently full and the suction lance are securely screwed to the containers Only one DOS system can be vented at a time Open the menu as follows Button Settings Priming DOS system DOS name of dispensing system Priming DOS system DOS Automatic venting will start when the dispensing system is selected Once started the automatic venting process can no longer be cancelled Select a dispensing sy...

Страница 64: ...e Settings and Language menu options acts as a guide if a language which you do not understand has already been set before Language english GB english USA A list will appear in the display with all the languages available The currently selected language has a tick beside it The factory default language is set as english GB For Canada select English CA or Français CA Use the and arrow buttons to se...

Страница 65: ...e set Select the date format The selected date format appears in the display and in the process documentation Open the menu as follows Button Settings Date Date format Date format DD MM YY MM DD YY DD Day MM Month and YY Year Use the and arrow buttons to select the date format you want Press OK to save the setting ...

Страница 66: ...n is pressed the display jumps automatically to the next input position You cannot go back to the previous entry If a mistake is made the process must be cancelled using the button and repeated Use the arrow buttons higher and lower to set the day month and confirm your entry using the OK button Use the arrow buttons higher and lower to set the year and press the OK button to save the date The dat...

Страница 67: ...time daylight savings and winter time You need to make this adjustment yourself as necessary Select Clock display To set the format for the time of day in the display Open the menu as follows Button Settings Time of day Time format Time format 12 h 24 h 12 h Time of day display in 12 hour format am pm 24 h Time of day display in 24 hour format Use the and arrow buttons to select the date format yo...

Страница 68: ...tion with the OK button When the OK button is pressed the display jumps automatically to the next input position You cannot go back to the previous entry If a mistake is made the process must be cancelled using the button and repeated Use the arrow buttons higher and lower to set the minutes and press the OK button to save the time of day The time of day will be saved when the OK button is pressed...

Страница 69: ...ay Display Display Do not display On On Time of day is constantly displayed when the machine is switched off On for 60 seconds Time of day is displayed for 60 seconds when the machine is switched off Do not display The display is switched off when the machine is switched off Select an option using the and arrow buttons Press OK to save the setting ...

Страница 70: ...eypad tone Setting the buzzer volume for keypad tone Select an option using the and arrow buttons Confirm your selection with OK When Keypad tone has been selected you can adjust the volume immediately When Buzzer tones has been selected you must first select for which tone Warning or Program end you would like to adjust the volume Program end Louder Quieter Keypad tone Quieter Louder The volume l...

Страница 71: ...ing the button In the structure overview all options which can be permanently selected have boxes beside them Factory settings are indicated by a tick You will find an explanation of how to change settings after the overview Additional settings Code Program cancellation Code required Code not required Change code Log book Consumption Water Consumpt Cleaning agent Consumpt Rinse aid Consumpt Neutra...

Страница 72: ...OS system Concentration Change name Test program No Laboratory Validation Interface Ethernet RS232 Water hardness 19 Display view Actual temperature Required temperature Display Contrast Brightness Switch off after Yes No Factory default Reset Program settings only All settings No Software version EB ID XXXX EGL ID XXXX EZL ID XXXX EFU ID XXXX ...

Страница 73: ...pted to enter the PIN code when it is selected PIN Code If you do not have the PIN code contact a user with appropriate access rights or cancel the process using the button Use the arrow buttons higher and lower to enter the relevant digits Confirm each digit individually with the OK button When the OK button is pressed the display jumps automatically to the next input position You cannot go back ...

Страница 74: ...ption of cancelling a program can be blocked using the PIN code Open the menu as follows Button Additional settings Code Program cancellation Program cancellation Code not required Code required Code required A program can only be cancelled by entering the PIN code Code not required All users can cancel running programs at any time Select an option using the and arrow buttons Press OK to save the ...

Страница 75: ...Miele Service Open the menu as follows Button Additional settings Code Change code PIN Code Use the arrow buttons higher and lower to enter the relevant digits Confirm each digit individually with the OK button When the OK button is pressed the display jumps automatically to the next input position You cannot go back to the previous entry If a mistake is made the process must be cancelled using th...

Страница 76: ...sumpt Cleaning agent Display the total amount of liquid cleaning detergent used in litres l Consumpt Rinse aid Display the total amount of rinse aid used in litres L Consumpt Neutralizer Display the total amount of neutralizing agent used in litres L Operating hours Display the total number of operating hours Program cycle counter Total of all completed programs There is no breakdown of individual...

Страница 77: ...perature displayed is automatically recalculated Open the menu as follows Button Additional settings Temperature unit Temperature unit C F C Display temperature in degrees Celsius F Display temperature in degrees Fahrenheit Select an option using the and arrow buttons Press OK to save the setting Program settings You can use this menu to customize the current program to suit technical requirements...

Страница 78: ...ree To reduce this effect the heated air can be cooled down during the drying phase using a fine spray in the steam condenser Cooling in the steam condenser will increase water consumption Open the menu as follows Button Additional settings Air cooling Air cooling No Yes Yes Hot air is cooled using the steam condenser No Hot air is released uncooled into the room Select an option using the and arr...

Страница 79: ...ction of programs are available for use Select an option using the and arrow buttons and confirm your selection with OK The Selection option displays a list of all programs Release program Universal Accept Programs are selected by multiple choice A box is shown next to all programs in the list If a program is released there is a tick in the box An empty box indicates a blocked program Programs can...

Страница 80: ...red from 1 n The first three programs in the list are allocated to the program selection buttons 1 Universal on program selection button 2 Standard on program selection button 3 Intensive on program selection button 4 Inorganic 5 Organic etc Use the and arrow buttons to select the program you would like to move Confirm your selection with OK Now you can move this program within the list Use the an...

Страница 81: ...tems Individual dispensing systems can be activated or deactivated for all programs as follows Open the menu as follows Button Additional settings Dispensing system DOS name of dispensing system DOS Inactive Active Active The selected dispensing system is activated Dispensing will only occur in the appropriate wash blocks see Program charts Inactive The selected dispensing system is deactivated fo...

Страница 82: ...ciently full and the suction lance are securely screwed to the containers Only one DOS system can be vented at a time Open the menu as follows Button Additional settings Dispensing system DOS name of dispensing system Priming DOS system Priming DOS system DOS Automatic venting will start when the dispensing system is selected Once started the automatic venting process can no longer be cancelled Se...

Страница 83: ...essing result Consumption of liquid agents is recorded in the log book see Further settings Log book Changing program parameters on a validated machine will necessitate a renewed performance validation Open the menu as follows Button Additional settings Dispensing system DOS_ Concentration Concentration 0 01 2 00 0 30 Dispensing concentration can be adjusted in increments of 0 01 The possible rang...

Страница 84: ...ed using the options shown in the bottom line The top line shows which option has been selected from the bottom line Names may consist of up to 15 characters including spaces The following options are available Letters from A to Z each new word will start with a capital letter Numbers from 0 to 9 Space Use the symbol to delete the last position The name is saved when the OK symbol in the display i...

Страница 85: ...nd comes with its own operating instructions Only use terminal devices PC printers etc which comply with CAN CSA C22 2 No 60950 1 or UL 60950 1 Contact Miele for more information about communication modules software suitable printers and the Miele Remote Service Ethernet The XKM 3000 L Med communication module enables the establishment of an Ethernet interface for digital archiving of process data...

Страница 86: ...petent persons Open the menu as follows Button Additional settings Interface Interface Ethernet RS232 Ethernet Configuration of an Ethernet interface RS232 Configuration of a serial RS232 interface Select the type of interface and confirm your selection with OK Then the parameters for the interface must be configured ...

Страница 87: ...meters IP address Subnet mask Standard gateway DNS Server automatic DNS Server 1 DNS Server 2 Port type Port RS 232 Print reports Subsequent selection of cycle reports see Process documentation Status Connection status displayed On Off Language Any one of the following languages can be set for the RS232 interface German English French Italian Spanish Interface function Using the interface for proc...

Страница 88: ...ck is displayed Open the menu as follows Button Additional settings Display view Display view Actual temperature Required temperature Actual temperature Display the current actual temperature in the wash cabinet Required temperature Display the required temperature which has been preset for the current wash block If a temperature has not been set a dotted line is shown During a program both settin...

Страница 89: ...lay Brightness Contrast Contrast Set the contrast Brightness Set the brightness Select an option using the and arrow buttons Confirm your selection with OK Brightness Brighter Darker Contrast Lower Higher Contrast and brightness are shown as a bar chart in the display Use the arrow buttons Higher Brighter and Lower Darker to set the brightness and contrast you want Press OK to save the setting ...

Страница 90: ...be set after which automatic switch off should occur No The Auto Off function is deactivated Select an option using the and arrow buttons Press OK to save the setting Setting the standby duration If the Yes option has been selected the standby duration after which automatic switch off should occur must be set next Switch off after Min 5 120 60 Min The standby duration can be adjusted in 5 minute i...

Страница 91: ...meters including dispensing quantities and water hardness will be reset Select an option using the and arrow buttons Confirm your selection with OK By selecting All settings the machine is being restarted After restarting you are prompted to enter basic parameters such as language date time water hardness etc again Enter language date time etc Select the Drain program and press the Start Stop butt...

Страница 92: ...once in a program The so called program header is placed above the program blocks and contains general program settings Individual wash block parameters are also globally activated or deactivated here Program header Spray arm monitoring It is possible to monitor spray arm rotation in selected wash blocks Conductivity limit The conductivity of the water in the final rinse phase is monitored using a...

Страница 93: ...ccurs at temperatures between 50 C and 85 C 104 140 F with the addition of an appropriate cleaning detergents Rinse 1 to 4 In the interim rinse stages the process chemicals from the previous wash blocks are rinsed away and neutralized by the addition of neutralizing agents Final rinse 1 to 2 To avoid deposits on the wash load demineralized water DI should preferably be used if available for the fi...

Страница 94: ...y Miele Service Open the menu as follows Button Additional settings Program settings Program settings Change program Reset program Change program Programs can be adapted to suit specific technical requirements Reset program Reset a program to factory default settings Programs newly installed by Miele Service will be deleted with this option ...

Страница 95: ...eleted Program settings Reset program All programs are then listed in the display Use the and arrow buttons to select the program and confirm your selection with OK Reset program Yes No Yes The program will be reset to factory default No Program parameters will not be changed Use the and arrow buttons to select an option and confirm your selection with OK ...

Страница 96: ...ogram or the existing allocation confirmed again Only allocated program blocks can be parameterized Then the program parameters can be altered Document all changes of factory settings in case of a subsequent Service call Changing program parameters on a validated machine will necessitate a renewed performance validation Program settings Change program Change program Universal Standard Select the p...

Страница 97: ...ash block is allocated to the program by ticking the box or the allocation can be removed by removing the tick The wash blocks can be selected or deselected using the and arrow buttons and confirming with OK To save the selection select the Accept option at the end of the list and confirm with OK If you want to adopt the preset wash blocks without any changes you can confirm the Accept option imme...

Страница 98: ...models and therefore these cannot be monitored If the rotation speed detected is not within a pre set range a warning message is shown in the display This allows e g blockages due to loading errors or build up of foam in the water circulation system to be identified and dealt with promptly The rotation speed range depends on the area of application the program and the wash cart or basket used If t...

Страница 99: ...nitoring Off for basket On Off Spray arm monitoring is switched off Off for basket Only the machine spray arms are monitored The sensors for baskets or wash carts are deactivated This setting also can be used when older basket and wash cart models are used On All spray arms are monitored Select an option using the and arrow buttons Press OK to save the setting ...

Страница 100: ...smosis unit optional accessory on site work on the water supply Interchanged water connections after maintenance work Possible causes for carry over of conductive substances from previous wash blocks are e g residual used water residual initial contamination residual process chemicals properties of items being processed e g items holding a lot of water that is carried from one program block to the...

Страница 101: ...the water at the end of the final rinse phase is measured Select an option using the and arrow buttons Press OK to save the setting Following selection a maximum limit value for electrical conductivity must be set Set limit value The limit values for Water intake and Water drainage are set individually Conductivity limit Water intake or Water drainage Set Water intake µS cm 5 200 µS cm µS cm 5 200...

Страница 102: ...led with a error message The message will be displayed both on the display and the cycle report Conductivity limit Water intake or Water drainage Number of repeats Number of repeats 1 0 1 Adjustment is in increments of 1 The possible range is shown in the bottom line Use the arrow buttons higher and lower to set the number of repetitions Press OK to save the setting Calibrating the conductivity me...

Страница 103: ... measurement occurs in the Final rinse 1 and Final rinse 2 wash blocks Conductivity Monitoring Conductivity Monitoring Yes No Yes Conductivity is measured No The conductivity sensor is deactivated Select an option using the and arrow buttons Press OK to save the setting ...

Страница 104: ... cart used the type of soiling and the load If a lightly soiled load is being reprocessed which does not hold much water the amount of water can be reset to the factory default amount to save water and energy Water volume change Water volume change 0 l 0 8 5 l The water quantity can be increased in 0 5 l increments or set back to the factory default amount The possible range is shown in the bottom...

Страница 105: ...o enable water to be drained out of the wash cabinet within the designated time Check drainage In this case the drainage time can be increased Drainage time Drainage time Standard Extended Standard The standard drainage time setting applies Extended Drainage time is increased by a strictly preset increment Program duration will increase with this setting Select an option using the and arrow button...

Страница 106: ...vary according to model and the number of connected DOS modules Select an option using the and arrow buttons and save your choice with OK Then you can set the dispensing concentration in percent DOS 0 01 2 00 0 3 Adjustment is in 0 01 increments The possible range is shown in the bottom line Please observe the concentration recommendations of the process chemicals manufacturer Use the arrow button...

Страница 107: ...vious wash block and the the incoming tap water temperature Set Setting a wash block temperature Select an option using the and arrow buttons Press OK to save the setting When Set is selected the wash block temperature must then be entered Wash block temp 60 30 93 C C Adjustment is in increments of 1 The possible range is shown in the bottom line Dispensing of process chemicals occurs at a default...

Страница 108: ...15 1 Min The duration can be set in 1 minute increments The possible range is shown in the bottom line If process chemicals are to be dispensed in this wash block the holding time will equal at least to the dispensing DOS contact time It is not possible to set a lower value Use the arrow buttons higher and lower to set the holding time Press OK to save the setting ...

Страница 109: ...ause the steam from the wash cabinet is fed into the steam condenser and condensed This reduces the humidity in the wash cabinet and assists drying Cooling down pause Cooling down pause Set No No The drying unit starts immediately after the rinse phase without a cooling down pause Set The cooling down pause is activated for a duration which can be set Select an option using the and arrow buttons a...

Страница 110: ... Setting the Temperature 1 Temperature 1 Temperature 1 75 50 115 C C Temperature is adjusted in 5 C increments The possible range is shown in the bottom line Use the arrow buttons higher and lower to set the temperature Press OK to save the setting Set Drying time 1 Drying time 1 Drying time 1 30 0 120 Min Min Holding time is adjusted in 1 minute increments The possible range is shown in the botto...

Страница 111: ...n the bottom line Use the arrow buttons higher and lower to set the temperature Press OK to save the setting Set Drying time 2 Drying time 2 Set Drying time 2 30 0 120 Min Min Holding time is adjusted in 1 minute increments The possible range is shown in the bottom line Use the arrow buttons higher and lower to set the holding time Press OK to save the setting ...

Страница 112: ...d before the start of every program Drying time 2 Time changeable Time changeable No Yes Yes Drying time can be set again and saved before the start of every program No The drying time cannot be changed Select an option using the and arrow buttons Press OK to save the setting ...

Страница 113: ...ying unit fan is not switched on Set The drying unit fan will run for a specified duration Select an option using the and arrow buttons and confirm your selection with OK When Set has been selected the duration of the cooling down pause must then be set Cooling down with fan 120 10 200 s s Duration is set in 10 second increments The possible range is shown in the bottom line Use the arrow buttons ...

Страница 114: ...ontact Miele for more information on this Memory Depending on scale between 10 and max 20 cycle reports are stored in an internal power failure safe memory within the machine In the event of e g network or printer problems these can be subsequently recalled If the memory is full the oldest report is overwritten Raw data for a graphic output of process data from the last program is also stored Thes...

Страница 115: ...ion using external software option For digital archiving the process data is transmitted to external process documentation software via an Ethernet interface Transmission can optionally occur continuously during the process or as a single data packet at the end of the process The settings for this are modified by Miele Service Information on wash pressure A0 value conductivity and temperature in t...

Страница 116: ...m two different report formats for paper archiving In long format all recorded data is included Short format includes only selected parameters The report format has no effect on the data stored in the machine All the data required for a long report is stored so the report format can be changed for each new cycle Open the menu as follows Button Additional settings Report Report Long Short Short Pri...

Страница 117: ...able for printing reports retrospectively Open the menu as follows Button Additional settings Interface RS232 Print reports Transfer reports Current work day Last report Last report Output of the last cycle report Current work day Output of all cycle reports for the current working day Last working day Output of all cycle reports for the previous working day All Output of all saved reports Select ...

Страница 118: ... non return valve All wash carts baskets inserts and modules Steam condenser Wash pressure sensor Drying unit Where applicable Conductivity meter If there is a communication module Connected printer Network connection External documentation software and the computer network will not be tested by Miele The following operational tests will be carried out within the framework of the maintenance A pro...

Страница 119: ...All wash carts baskets inserts and modules Cleaning the filters in the wash cabinet The filters in the floor of the wash cabinet prevent coarse soiling from coming into contact with the circulation system Filters can become blocked by soiling so they need to be checked every day and cleaned as necessary This machine must not be used without all the filters in place Danger of injury from glass shar...

Страница 120: ...coarse filter and the microfine filter Remove the flat filter last Clean the filters Re insert the filter combination in the reverse order Ensure that the flat filter sits flat in the base of the wash cabinet that the coarse filter has securely clicked into place in the microfine filter that the microfine filter is tightly screwed in as far as it will go ...

Страница 121: ... baskets must be fully dismantled for cleaning Remove the wash cart or baskets from the machine The upper spray arm of the machine is connected by a push fit connector Pull the upper spray arm of the machine downwards to remove it The lower spray arm of the machine and the spray arms in the wash carts and baskets are secured with bayonet fittings To release the knurled bayonet fittings turn them i...

Страница 122: ...e magnets Check the spray arm bearings for visible signs of wear Visible wear on the bearings can adversely affect the long term functioning of the spray arms In this case contact Miele Service Replace the spray arms after cleaning Make sure the spray arms can rotate freely after they have been fitted The spray arms and baskets each have a number e g 03 which is also embossed on the water supply p...

Страница 123: ...isinfectants such as Hydrogen Peroxide and Paracetic Acid Cleaning the door and the door seal Wipe the door seal regularly with a damp cloth to remove soiling Have damaged or leaking door seals replaced by Miele Service Remove any soiling from the door sides and hinges Regularly clean the groove in the base panel under the door with a damp cloth Cleaning the wash cabinet The wash cabinet is largel...

Страница 124: ... Are all injector nozzles sleeves and hose adapters clear so that wash fluid can flow through unhindered Are all caps covers and fasteners securely attached to the spray sleeves Are end caps present and securely located for all modules and injector manifolds Are the locking caps in the water connectors of wash carts and baskets working properly Where applicable Do the spray arms rotate freely Are ...

Страница 125: ...nder the lid or worktop is the test point for validation purposes To gain access to this the lid of the machine must be removed or the machine must be pulled out from under the worktop Open the door Unscrew the fixing screws Then remove the safety screws on the back of the machine from the lid and lift the lid to remove it or Pull the machine out by approx 15 cm from under the worktop ...

Страница 126: ...ples To prevent the wash cabinet from cooling down do not leave the door open for too long The program will recommence after the 30 seconds has elapsed If the door was opened the program can only restart when the door is closed If you do not want to take measurements or samples you can continue the program early by pressing the Start Stop button The following test programs can be selected Laborato...

Страница 127: ...ratory test program Validation Activates the Validation test program Select an option using the and arrow buttons Press OK to activate the test program for the next program start You can now start the performance test Select and start a program using the program selection buttons or via the program list The program will be identified in the bottom line as Test program during the program sequence I...

Страница 128: ...h an Original Miele HEPA filter classification 13 for optimum performance Open the service panel in the toe kick Push the retaining clips outwards to release the HEPA filter Grasp the indentations on the sides and pull the filter forwards Insert a new HEPA filter making sure that it locates securely in the retaining clips Close the service panel Whenever the HEPA filter is replaced the operating h...

Страница 129: ...ange HEPA filter Filter life remaining 55 h The remaining operating hours for this filter type is shown in the display Confirm the message with OK Then you will be asked if you wish to reset the operating hours counter The operating hours counter must only be reset when the filter has been changed Reset counter Yes No No The counter will not be reset Yes The operating hours counter will be reset f...

Страница 130: ...ay is dark and all LEDs are out The machine is not switched on Switch the machine on using the button A breaker is defective or has tripped Refer to the minimum fuse rating on the data plate Reset the trip switch If the mains breaker trips again call Miele Service The machine is not plugged in Insert the plug The machine has switched itself off This is not a fault The Auto Off function switches th...

Страница 131: ...ry Check the fill level in the supply container Replace the empty container with a full one if needed Vent the dispensing system Dispensing system DOS priming This is not a fault The dispensing system will now be automatically vented Wait until the venting process is finished Priming DOS canceled Priming must be repeated Venting of the dispensing system was cancelled because an insufficient flow r...

Страница 132: ...sits Vent the dispensing system The dispensing hose is kinked Remove any kinks from the dispensing hose Position it so that it cannot become kinked Check the dispensing hose for leaks Vent the dispensing system Contact Miele Service if there are leaks in the dispensing hose or a fault with the suction lance Highly viscous thick process chemicals can affect the dispenser monitoring and lead to inac...

Страница 133: ... empty Program locked The water softener cannot reactivate because there is insufficient salt The machine is locked for further use Refill with reactivation salt The lock is lifted a couple of seconds after refilling the salt reservoir Reactivation will occur automatically during the next program sequence Salt container lid not closed correctly The salt container is not closed properly Close the c...

Страница 134: ...s Problem Possible cause and remedy Fault 403 405 A program has been cancelled because water intake by the machine was insufficient or severely restricted Turn on the taps fully Follow the further information given in the Check water intake message Fault 406 408 A program was cancelled because the water inlet volume is insufficient Check whether the taps are fully turned on Refer to the informatio...

Страница 135: ...sing from an external supply container Caution when handling process chemicals For all process chemicals the process chemical manufacturer s safety instructions as given on their safety data sheets must be observed Check the level of the container and replace it as necessary Check the suction openings of the suction lance and remove any deposits Check the hose connections on the suction lance the ...

Страница 136: ...A test program is running to check performance At certain points in the program the sequence is interrupted so that samples can be taken Take a sample or Wait The program will continue automatically in approx 30 seconds or Continue the program without delay by pressing the Start Stop button Program cancelled This is not a fault A program which was running was cancelled by the user The wash cabinet...

Страница 137: ... objects in front of the machine can impede the automatic opening of the door by the Comfort lock Do not place heavy objects in front of the door of the machine The Comfort door lock is blocked Try to open the door carefully without using force by pulling on the door handle If the door is still blocked Open the door using the emergency release Close the door and try to open it again using the butt...

Страница 138: ...replace the demineralization cartridge with a new one The cleaning result is unsatisfactory Wash carts baskets modules and inserts were not suitable for the load Select wash carts baskets modules and inserts which are suitable for the task Wash carts baskets inserts and modules were incorrectly loaded or overloaded Arrange the wash load correctly according to the information in the Operating instr...

Страница 139: ...ng detergent Stainless steel items are showing signs of corrosion The stainless steel is of insufficient quality for machine reprocessing Only use stainless steel items made of high quality stainless steel and follow the instructions of the manufacturer regarding machine reprocessing The chloride content in the water is too high Have a water analysis check carried out Connection to an external wat...

Страница 140: ...build up in Chemical processes and technology Start the Rinse program to clean the wash cabinet Prepare the load again Conductivity level too high Actual value µS cm Max value µS cm Carry over of conductive substances during reprocessing Check the process Empty or faulty water softener or demineralization system Check external water softener or demineralization systems Reactivate the systems if ne...

Страница 141: ...apters foam build up Identify and resolve the cause of this The program was not interrupted however the wash load must be reprocessed again Spray pressure fluctuating too much The program was cancelled because the spray pressure has deviated by more than 40 from the mean value Reasons for fluctuations in spray pressure are e g defective water connections open adapters foam build up Identify and re...

Страница 142: ... water drains away slowly or cannot drain away because the drain hose is blocked Remove any kinks or large loops in the drain hose Re start the program the filters in the wash cabinet are blocked Cleaning the filters in the wash cabinet Danger of injury from glass shards needles etc which are retained in the filter Re start the program the drain pump or non return valve are blocked Cleaning the dr...

Страница 143: ...y arms Make sure the spray arms can rotate freely Re start the program Rattling noise in the wash cabinet Items are insecure in the wash cabinet Cancel the program To do this follow the instructions in Cancelling a program Rearrange the load so that items are secure Re start the program Knocking noise in the water pipes This may be caused by the on site installation or the cross section of the pip...

Страница 144: ...he configuration of the interface checked by a suitably qualified person If the printer has been replaced the printer type must be adjusted in the interface configuration Serial printer fault general fault The printer is not ready for operation Check the printer for fault messages Change the printer cartridge if necessary Network down The communication module has identified a network interruption ...

Страница 145: ...ift the locking clamp Lift out the non return valve and rinse well under running water Make sure that the vent on the external part of the non return valve is not blocked This vent is only visible when the non return valve has been taken out If it is blocked use a pointed object to release the blockage The drain pump impeller is situated under the non return valve see arrow Check the impeller for ...

Страница 146: ...he machine off unplug it or disconnect or disable the breaker Turn off the tap Unscrew the water inlet valve Carefully pull the large surface area filter 1 out Take the seal ring out of the screw connection Withdraw fine filter 2 using pointed pliers Clean the filters or replace them with new ones if necessary Replace the filters and seals making sure they are sitting correctly Reconnect the hose ...

Страница 147: ...formation in Problem solving guide If having followed the advice in the operating instructions you are still unable to resolve a problem please call Miele Service see the end of this booklet for contact details Contact details can be found at the end of this manual When contacting Miele Professional Service please quote the model number and serial number of your machine These are shown on the data...

Страница 148: ... EGL Id XXXXX The software units are listed in the display XXXXX stands for the relevant version number EB Id XXXXX Software version of the control and display units in the control panel EGL Id XXXXX Software version of the control board EZL Id XXXXX Software version of the relay board EFU Id XXXXX Software version of the frequency converter You cannot change any settings in this menu Software upd...

Страница 149: ...ness in the floor level and height of the machine can be compensated for by adjusting the four feet The feet can be screwed out to a maximum of 6 cm The machine is suitable for the following types of installation Freestanding Slot in The machine can be installed beside other appliances or furniture or in a suitable niche The niche must be at least 600 mm wide and 600 mm deep Built under The machin...

Страница 150: ...moved as follows Unscrew both securing screws from the lid at the back of the machine Open the door Unscrew the left and right fixing screws Lift the lid off Steam condenser To avoid steam damage to the worktop the protective foil supplied 25 x 58 cm self adhesive must be applied underneath the worktop in the area of the steam condenser ...

Страница 151: ... Miele to secure it at the sides to adjacent cabinetry Venting the circulation pump The gaps between a built in machine and adjacent cabinetry must not be filled with silicone sealant as this could compromise the ventilation of the circulation pump Cover plate Worktop protector A cover plate worktop protector is available from Miele and may be advisable depending on building in location The cover ...

Страница 152: ...ains power supply The machine s HF emissions are very low and are therefore unlikely to interfere with other electronic appliances in the vicinity Flooring in the installation area must be wood concrete or tiled Synthetic flooring must be able to withstand a relative humidity level of 30 to minimise the risk of electrostatic discharges The quality of the power supply should comply with that found ...

Страница 153: ...ee the data plate or the attached wiring diagram For added safety it is advisable to protect the machine with a suitable residual current device RCD with a trip current of 30 mA Contact a qualified electrician for advice If replacing the power cord use only original Miele replacement parts or a suitable cord with core cable ends Further notes on electrical connection are given on the Installation ...

Страница 154: ...e coded hose and optionally to hot water up to max 65 C red coded hose Connect the inlet hoses to the water shut off valves for cold and hot water If there is no hot water supply available the inlet hose coded red must be connected to the cold water supply or alternatively has to be deactivated by a Miele Service technician The intake hose without water protection device for the steam condenser is...

Страница 155: ...may the inlet filter be removed Install the filter supplied in accessory pack between the stopcock valve and the inlet hose The filter for DI water is made of chromium nickel steel and can be recognized by its dull surface and green label Do NOT shorten or otherwise damage the inlet hoses See installation diagram supplied ...

Страница 156: ... going to be connected to DI water the DI water connection has to be deactivated by a Miele Service technician The inlet hose remains in position at the back of the machine Non pressurized gravity feed DI water connection 1 3 8 7 psi 8 5 60 kPa If DI water is supplied from a DI water reservoir with gravity feed or low pressure an optional DI water booster pump supplied by Miele is required The pre...

Страница 157: ...rain temperature to 60 C 140 F The on site connection point measured from the lower edge of the machine should be positioned at a height between 0 3 m and 1 0 m 1 3 2 ft If it is lower than 0 3 m the drain hose must be laid in a coil at a height of at least 0 3 m The drainage system must be able to accommodate a minimum drainage flow of 16 l min The drainage hose is approx 1 4 m 4 6 ft long and fl...

Страница 158: ...age time On Standard Off for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 No Drying time 2 Set seconds Set Min Temperature 1 Time changeable Yes No Drying time 1 Min Cooling dow...

Страница 159: ...peats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 160: ...age time On Standard Off for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 No Drying time 2 Set seconds Set Min Temperature 1 Time changeable Yes No Drying time 1 Min Cooling dow...

Страница 161: ...peats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 162: ... Off Wash block Pre wash Parameters 1 2 3 Water quality CW50 Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min Cooling down with fan No Set s...

Страница 163: ...er of repeats 0 1 Number of repeats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 HW HW HW DI DI DOS 1 DOS 3 0 3 0 1 75 C 75 C 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent ...

Страница 164: ...ime On Standard Off for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Mi...

Страница 165: ...ats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 CW50 HW DI DI DOS 1 DOS 3 0 4 0 1 70 C 70 C 3 2 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 166: ... Off Wash block Pre wash Parameters 1 2 3 Water quality CW50 Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min Cooling down with fan No Set s...

Страница 167: ...r of repeats 0 1 Number of repeats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 HW HW DI DI DI DOS 1 DOS 3 0 4 0 1 80 C 75 C 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent D...

Страница 168: ...ck Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min Cooling down with fan No Set seconds 120 ...

Страница 169: ...Water drainage Set µS cm Set µS cm Number of repeats 0 1 Number of repeats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 CW50 HW HW DI DI DI DOS 3 DOS 1 DOS 3 0 3 0 4 0 1 50 C 75 C 70 C 2 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time ...

Страница 170: ...me On Standard Off for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min...

Страница 171: ...mber of repeats 0 1 Number of repeats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 HW HW HW HW DI DI DOS 1 DOS 1 DOS 3 0 4 0 3 0 1 65 C 85 C 75 C 3 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS...

Страница 172: ...er volume change l Spray arm monitoring Drainage time On Standard Off for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality CW50 Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min...

Страница 173: ...1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 HW HW HW DI DI DOS 1 DOS 3 0 3 0 1 75 C 75 C 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 174: ... Parameters 1 2 3 Water quality CW50 Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 80 C 176 F No Drying time 2 Set seconds 30 Set Min 35 Temperature 1 Time changeable Yes No Drying time 1 Min Cooling down with fan No Set seconds 120 ...

Страница 175: ...l rinse 1 2 1 2 3 4 1 2 HW HW DI DI DI DOS 1 DOS 3 0 4 0 1 70 C 70 C 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 176: ...xtended Off Wash block Pre wash Parameters 1 2 3 Water quality CW Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 70 C 167 F No Drying time 2 Set seconds Set Min 15 Temperature 1 80 C 176 F Time changeable Yes No Drying time 1 Min 30 Cooling down wi...

Страница 177: ...er of repeats 0 1 Number of repeats 0 1 Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 CW CW CW DI DI DOS 1 DOS 3 0 3 0 1 55 C 55 C 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent ...

Страница 178: ... basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min Cooling down with fan No...

Страница 179: ... Final rinse 1 2 1 2 3 4 1 2 HW HW DI DOS 1 DOS 3 0 3 0 1 60 C 60 C 3 2 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 180: ...nded Off Wash block Pre wash Parameters 1 2 3 Water quality HW Dosage 1 Dispensing system DOS 4 Concentration 0 5 2 Dispensing system DOS 1 Concentration 0 3 Wash block temperature 45 C Holding time Min 1 Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 110 C 230 F No Drying time 2 Set seconds 30 Set Min 30 Temperature 1 Time changeable Yes No Drying time 1 Min Coo...

Страница 181: ... Cleaning Rinse Final rinse 1 2 1 2 3 4 1 2 HW HW HW HW DI DI DOS 4 DOS 1 DOS 3 0 4 0 3 0 1 DOS 1 0 4 65 C 85 C 75 C 2 3 2 1 1 1 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS...

Страница 182: ...for basket Extended Off Wash block Pre wash Parameters 1 2 3 Water quality Dosage 1 Dispensing system Concentration 2 Dispensing system Concentration Wash block temperature Holding time Min Conductivity Monitoring conductivity Drying unit Cooling down pause Temperature 2 95 C 203 F No Drying time 2 Set seconds 30 Set Min 50 Temperature 1 100 C 212 F Time changeable Yes No Drying time 1 Min 20 Cool...

Страница 183: ...al rinse 1 2 1 2 3 4 1 2 CW70 HW HW DI DOS 1 DOS 3 0 6 0 1 93 C 75 C 10 1 1 3 On Customizable parameters CW cold water HW hot water CWxx CW proportion in mixed water as percentage CW70 70 CW 30 HW DI aqua destillata fully demineralised water demineralized water Min Holding time in minutes DOS 1 cleaning detergent DOS 3 neutralizing agent DOS 4 DOS module ...

Страница 184: ...lication Cold water rinse holding time 1 Min For flushing out saline solution see Water softener rinsing heavily soiled loads e g for pre rinsing soiling residual disinfecting agent or to prevent items drying out and to prevent incrustation before running a full load Drain Application For draining suds e g after a program cancellation see Operation Cancelling a program ...

Страница 185: ...ter Steam condenser 29 psi 29 psi 14 5 psi 200 kPa 200 kPa 100 kPa Drainage pumping height min 11 3 4 ft max 3 3 ft min 0 3 m max 1 0 m Drain hose length max 13 1 ft max 4 0 m Ambient temperature 40 F to 104 F 5 C to 40 C Relative humidity maximum linear decreasing to 80 for temperatures up to 88 F 50 for temperatures up to 104 F 80 for temperatures up to 31 C 50 for temperatures up to 40 C Altitu...

Страница 186: ... sites Disposing of your old appliance Old electrical and electronic equipment often still contain valuable materials However they may also include harmful substances that were essential for proper functioning and safe use Improperly disposing of these items in your household waste can be harmful to your health and the environment Therefore please do not dispose of your old appliance in your regul...

Страница 187: ......

Страница 188: ...8 Phone Fax www mieleprofessional ca professional miele ca Miele ProfessionalTechnical Service 1 888 325 3957 1 800 803 3366 Phone Fax serviceprofessional miele ca Germany Manufacturer Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Canada Alteration rights reserved Publication date 2016 01 27 M Nr 10 284 370 00 ...

Отзывы: