55
H 408x BM
6. Remove the four T20 screws securing the bottom of the fan rear panel
(Figure 032-6, Item 4).
7. Remove the fan rear panel with convection fan and convection heater.
Note:
The impeller retaining nut is a left-hand thread.
8. Unscrew the nut securing the impeller.
9. Remove the impeller.
Figure 032-6:
Fan Impeller Removal
Note:
After installation of the fan rear panel, replace the bottom insulation strip.
Danger!
After installation is completed, as a matter of standard practice, check the
oven for a tight seal with a microwave leak detector, paying particular attention
to the door and the housing edges.
4.2
Convection Fan (M2/2) Removal
1. Remove the appliance from its cabinet (refer to Section 011-4.3).
2. Remove the impeller. See Section 032-4.1.
3. Remove the convection fan retaining screws.
4. Remove the convection fan.