Technical Information
42
H 408x BM
7. Perform the high-voltage transformer test. Refer to Section 012-4.12.
8. Perform the high-voltage capacitor checks. Refer to Sections 012-4.14
and 012-4.15.
9. Perform the magnetron test procedure. Refer to Section 012-4.8.
10. Perform the V1 diode test (Section 012-4.16) and the V6 protective diode
test (Section 012-4.17).
11. Reassemble the appliance.
12. Access the oven cavity, remove the ceiling cover retaining screws and
ceiling cover.
13. Restore power to the appliance.
14. Briefly perform the microwave output test (Section 012-4.11) and verify
that the wave distributor motor is functioning (turning).
15. If all components/test(s) check okay, perform the following:
a. Disconnect the appliance from power (unplug/shut off circuit breaker).
b. Discharge the high-voltage capacitor. See Section A-2.
c. Replace the power electronic.
Содержание H 4080 BM
Страница 1: ...TECHNICAL INFORMATION H 408x BM Speed Ovens 2013 Miele USA ...
Страница 15: ...Technical Information 15 H 408x BM 011 Casing Door Lock ...
Страница 25: ...Technical Information 25 H 408x BM 012 Air Duct Magnetron ...
Страница 43: ...Technical Information 43 H 408x BM 020 Door ...
Страница 47: ...Technical Information 47 H 408x BM 031 Oven Cavity Wave Distribution ...
Страница 52: ...Technical Information 52 H 408x BM 032 Convection Fan Heaters ...
Страница 58: ...Technical Information 58 H 408x BM 040 Control Panel Electrical System ...