![Midea IC SI-A-1205 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/midea/ic-si-a-1205/ic-si-a-1205_service-manual_1791255053.webp)
53
Spec.
Code
2T0032300776
2T0032400215
Indoor code
220032308300
220032402810
Indoor
MSIC-09HRDN1-QC2
MSIC-12HRDN1-QC2
Outdoor code
220037305880
220037401990
Outdoor
MOR-09HDN1-QC2
MOR-12HDN1-QC2
Compressor
DA89X1C-23EZD1
DA89X1C-23EZD1
Indoor fan motor
RPG20E
RPG20E
Outdoor fan motor
YDK24-6P(B)
YDK24-6P(B)
2. Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
DA89X1C-23EZD1
Blue - Red
1.1Ω
(20
℃
)
Blue - Black
Red - Blue
Содержание IC SI-A-1205
Страница 1: ...IC INVERTER SERIES Service Manual 2012 ICSI A 1205...
Страница 10: ...10 Model W D H W1 A B MOR 09HDN1 QC2 660 265 540 732 458 276 MOR 12HDN1 QC2...
Страница 12: ...12 5 Wiring Diagram 5 1 Indoor Unit MSIC 09HRDN1 QC2 MSIC 12HRDN1 QC2...
Страница 13: ...13 5 2 Outdoor Unit MOR 09HDN1 QC2 MOR 12HDN1 QC2...
Страница 24: ...24 Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage...