Running time in sleep mode is 9 hours. 9 hours later, AC will quit sleep mode.
●
When cooling, the default setting temperature is 25
℃
which will increase 1
℃
every one
hour,2 hours later the setting temperature stops rising.
●
When heating, the default setting temperature is 22
℃
which will decrease 1
℃
every one
hour, 2 hours later the setting temperature stops changing.
●
If the setting temperature is changed during X hours, it will be memorized and enabled as the
setting temperature of X~9 hours in the next time running while the setting temperature in the X-1
hours will not change.
●
The indoor fan runs at auto speed.
8.4.9 I mode
The “I mode” is used to restore the current settings or resume previous settings. Under cooling or
heating operation, push the “i mode” button of remote controller for more than half and one
second, the system will restore the current operation settings including operating mode, setting
temperature, fan speed level and swing feature(if activated ). On the first time pressing this button,
the unit will operate on COOL mode, 26
℃
(or HEAT mode, 20
℃
), and fan speed is auto.
8.4.10 Low-frequency operation with auto fan
This function is only available in cooling mode. Press “FUNCTION” button , then press the
“ADJUST“ to
and select “OK”. Then the function will be active.
During the function, the maximum running frequency will be limited and the indoor fan speed is
auto which is more energy-saving.
8.4 11 Dry and Self clean function
When the unit is turned off, it will run in fan only mode for 7 minutes, then run heat mode with low
fan for 1 minute, and then run fan only mode for 2 minutes. This function can provide you clean air
Содержание IC SI-A-1205
Страница 1: ...IC INVERTER SERIES Service Manual 2012 ICSI A 1205...
Страница 10: ...10 Model W D H W1 A B MOR 09HDN1 QC2 660 265 540 732 458 276 MOR 12HDN1 QC2...
Страница 12: ...12 5 Wiring Diagram 5 1 Indoor Unit MSIC 09HRDN1 QC2 MSIC 12HRDN1 QC2...
Страница 13: ...13 5 2 Outdoor Unit MOR 09HDN1 QC2 MOR 12HDN1 QC2...
Страница 24: ...24 Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage...