![Midea IC SI-A-1205 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/midea/ic-si-a-1205/ic-si-a-1205_service-manual_1791255039.webp)
39
8.4.7 Timer function
8.4.7.1 Timing range is 24 hours.
8.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time.
8.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time.
8.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting “on” time,
and then turn off automatically when reaching the setting “off” time.
8.4.7.5 Timer off/on. The machine will turn off automatically when reaching the setting “off” time,
and then turn on automatically when reaching the setting “on” time.
8.4.7.6 The timer function will not change the AC current operation mode. Suppose AC is off now,
it will not start up firstly after setting the “timer off” function. And when reaching the setting time,
the timer LED will be off and the AC running mode has not been changed.
8.4.7.7 The setting time is relative time.
8.4.8 Intelligent sleep mode
This function is only available in cooling mode and heating mode.
Two kinds of sleep modes are
optional. Press “FUNCTION” button to select.
Sleep mode A:
Running time in sleep mode is 8 hours. 8 hours later, AC will quit sleep mode and the setting
temp. decrease 1
℃
for cooling mode or increase 1
℃
for heating mode.
●
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hours
later the setting temperature stops rising.
When heating, the setting temperature decreases 1
℃
(be higher than 17
℃
) every one hour, 2
hours later the setting temperature stops changing .
●
The indoor fan runs at auto speed.
Sleep mode B:
Содержание IC SI-A-1205
Страница 1: ...IC INVERTER SERIES Service Manual 2012 ICSI A 1205...
Страница 10: ...10 Model W D H W1 A B MOR 09HDN1 QC2 660 265 540 732 458 276 MOR 12HDN1 QC2...
Страница 12: ...12 5 Wiring Diagram 5 1 Indoor Unit MSIC 09HRDN1 QC2 MSIC 12HRDN1 QC2...
Страница 13: ...13 5 2 Outdoor Unit MOR 09HDN1 QC2 MOR 12HDN1 QC2...
Страница 24: ...24 Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage...