![MICRO-EPSILON ODC 2600-40 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/micro-epsilon/odc-2600-40/odc-2600-40_operating-instructions-manual_1785350056.webp)
Page 56
Measure
optoCONTROL 2600
6.6.3.18 Reset the Light Reference Tuning
Name
RESET LIGHT REFERENCE TUNING
Description:
Erasures the flexible threshold value for dark/light transition, use of
a fixed threshold value for dark/light transition.
Command:
Byte 1
Byte 2
Byte 3
Byte 4
hex
„+“
„+“
„+“
0x0D
0x0D2B2B2B
„0“
„D“
„C“
„1“
0x3143444F
0x2D
0x20
0x00
0x00
0x0000202D
i
This command corresponds to the menu “1B30 - Reset Light Reference Tuning“.
Response:
Byte 1
Byte 2
Byte 3
Byte 4
hex
Remark
„0“
„D“
„C“
„1“
0x3143444F
0x2E
0xA0
0x03
0x00
0x0003A02E
Without error
0x00
0x00
0x00
0x00
0x00000000
Error code
6.6.4
Error Responses
0x04
Too much data received
0x06
Flash access error
0x0a
Error on writing to the RAM
0x0b
Incorrect data transmitted, see, ‘Valid values’
0x0c
Incorrect measurement program number
0x01
Error destination, if µC has to send information or data an error message is
returned e.g. passing data to the DSP were aborted
0x02
Error source, error during data fetching
0x03
Error length, stated length in the parameter > buffer size receiver
0x05
Not used
0x07
Error erase flash
0x08
Error flash sector, during writing or deletion of the flash
0x09
Error video, video can not be fetched by the DSP