Page 50
Measure
optoCONTROL 2600
Response:
Byte 1
Byte 2
Byte 3
Byte 4
hex
Remark
„0“
„D“
„C“
„1“
0x3143444F
0x27
0xA0
0x03
0x00
0x0003A027
Without error
0x00
0x00
0x00
0x00
0x00000000
Error code
Possible error codes:
0x00000004
Too much data received
0x0000000A
Error on writing to the RAM
0x0000000B
Incorrect data transmitted, see
Valid values
0x0000000C
Incorrect measurument program number
Avoid error!
> Data are not accepted!
6.6.3.11 Save Option Data
Name
SAVE OPT RAM TO FLASH
Description:
With this command the currently valid option data is written from
the main memory to the flash memory.
Command:
Byte 1
Byte 2
Byte 3
Byte 4
hex
„+“
„+“
„+“
0x0D
0x0D2B2B2B
„0“
„D“
„C“
„1“
0x3143444F
0x29
0x20
0x00
0x00
0x00002029
Response:
Byte 1
Byte 2
Byte 3
Byte 4
hex
Remark
„0“
„D“
„C“
„1“
0x3143444F
0x29
0xA0
0x03
0x00
0x0003A029
Without error
0x00
0x00
0x00
0x00
0x00000000
Error code
Possible error coder:
0x00000006
Flash access error
NOTICE
Содержание ODC 2600-40