Command Facility Administration
NetRunner W
AN User’s Manual
7-5
The following options are available.
Option
Description
1. Node
For the local node only. All locally attached MICOM muxes will
reset. Remote unit(s) and their MICOM muxes will not be reset by
this option. Two options for node reset are factory
default values
(cold start), or
current configuration
(warm start).
Notes:
D
If you are attempting to activate new software or a
FlashPak, you must use the Node: Flash Reload op-
tion. This option uses the current version of software.
D
The T1/E1 Access Module will not reset with this op-
tion. You must select the T1/E1 option for that reset
(NetRunner 500ET and 2000E,ED units).
2. Link
Clears all information on the link and
will disconnect all ports
cur-
rently using the link being reset.
If a mux link
, it will reset the MI-
COM mux also. Force connected channels will automatically rees-
tablish connection. Refer to Link Reset on page 4-30 for frame
relay link information.
3. Channel
Disconnects and resets a
single data or voice/fax channel only
without disturbing the whole network.
4. Integral LAN
Resets the integral LAN module (IRM).
5. or 6. (option number varies depending on unit)
D
T1/E1
Resets the T1 or E1 Access Module on the NetRunner 500ET or
2000E,ED. All traffic on the T1 or E1 access module and
associated Digital Voice Modules will be interrupted. The unit will
not reset.
D
Node:
Flash Re-
load
NetRunner 75E with single-bank Flash memory. Loads the soft-
ware from the Flash bank into RAM. This reset takes several min-
utes to complete.
D
Node: Bank
Selected
Software
If you have a dual-bank Flash memory installed and have pro-
ceeded through all the steps to download and select a bank, this
option resets the node and loads the selected bank into RAM.
This reset takes several minutes to complete.