LCD/Keypad
NetRunner WAN User’s Manual
6-2
Keypad Reset
The unit can be manually reset from the keypad by pressing the two outside
keys
and
at the same time and holding them for two seconds. This is a
hardware reset (warm start), and the current configuration will remain
unchanged, except for the time and date display which resets. This reset
does not require a password.
Within the Administration Menu of the LCD, there is a system reset (warm
start - current configuration, and cold start - default configuration), a link
reset, and channel reset function.
LCD/Keypad Password Protection
When configured, the LCD/Keypad password protects all the administrative,
diagnostic, and configuration functions, allowing access only to review the
alarm and status messages in the system message log.
The password may be a series of up to eight up, down, left, right arrows
followed by the EXEcute key. This sequence is entered in the Command
Facility as U, D, L, R characters followed by a <cr>. For example, after
configuring UUDL<cr> as the password, you would enter 2 up arrows, a
down arrow, a left arrow and EXEcute at the LCD/keypad when prompted for
the password.
Do not use commas when configuring. If no password is required, enter a
space during the password configuration.
The LCD/Keypad password is configured through the Command Facility, as
follows:
PASSWORDS
LCD/KEYPAD
CONFIGURE LOCAL NODES
PASSWORDS
COMMAND FACILITY MAIN MENU
CONFIGURE LOCAL NODES
3
3
Enter the desired sequence for the password.