Command Facility Administration
NetRunner W
AN User’s Manual
7-4
Keypad Reset
There are two types of node resets available from the keypad, a hardware
reset (which does not require a password), and the reset performed from
inside the menu functions software (refer to Menu Function Reset).
From the front of the unit, press the two outside keys (left arrow and EXEcute)
at the same time and hold for two seconds, as shown in the following diagram.
The unit will go into selftest.
Note:
Time and date are lost during a hardware reset, current configuration remains.
Simultaneously push
both outside keys and
hold for 2 seconds.
Backlight will
momentarily extinguish
Hardware Reset with LCD/Keypad
Command Facility Reset
In the Command Facility, several types of software resets are available. To
access the Reset menu, follow this path:
COMMAND FACILITY MAIN MENU [node ID]
RESET
RESET
1.
NODE
2.
LINK
3.
CHANNEL
4.
INTEGRAL LAN
5.
T1/E1
1
or
5.
NODE: FLASH RELOAD
2
6.
NODE: BANK SELECTED SOFTWARE
3
__________
1
Only displays on NetRunner 500ET and 2000E,ED units.
2
NetRunner 75E if only singlebank Flash memory.
3