Data Channels and Switching Configuration
NetRunner W
AN User’s Manual
5-34
Matrix Connection
Notes:
D
Do not attempt to matrix connect to any force connected port.
D
Matrix switching can be disabled on a per channel basis (Switching
Parameters Menu).
1. Complete the initial steps on page 532.
2. At the
ENTER CLASS
prompt, enter the full node ID/channel number of
the port to which you wish to connect.
3. If the destination port has been configured as a class, you will be
prompted for a class password; enter the password.
D
If the port is not available
, the screen will display,
Busy
Port is in use, try again.
No Answer
No answer from the destination port.
D
Remote port did not respond to
connection protocol.
D
No response within the call time
out period, although port is known
by the local unit.
Unavailable
Port exists, but is not in service or receive
inhibit is enabled.
Unassigned
The node or port is unknown to the
network or the password may be incorrect.
D
If the port is available,
the Class Message (if configured) and
CONNECTED
message will display.
Disconnecting
Press the
<break>
key three times within six seconds.
The disconnect
message will display on the screen.