![Michco sc8000 Скачать руководство пользователя страница 188](http://html1.mh-extra.com/html/michco/sc8000/sc8000_service-manual_1784517188.webp)
Squeegee System 187
Service Manual – SC8000
Squeegee Locked
When the squeegee is up (retracted), both
the
Squeegee Down Solenoid Valve L2
and
the
Squeegee Up Solenoid Valve L3
are
de-energized to shut off the flow of oil to
the
Squeegee Lift Cylinder
and lock the
squeegee in the up position.
250 psi Back
Pressure
Reservoir
Squeegee Down
Solenoid Valve L2
Squeegee Up
Solenoid Valve L3
Squeegee
Lift Cylinder
Содержание sc8000
Страница 18: ...General Information 17 Service Manual SC8000 Overall Dimensions...
Страница 81: ...Wiring Diagram Kubota 1 6L LPG Engine 56107659 REV A Electrical System 80 Service Manual SC8000...
Страница 111: ...Hydraulic System 110 Service Manual SC8000 Hydraulic Schematic...
Страница 124: ...Hydraulic System 123 Service Manual SC8000 Special Tools Hydraulic test gauge w connector 3000 psi range p n 56504516...