![Michco sc8000 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/michco/sc8000/sc8000_service-manual_1784517170.webp)
Solution System 169
Service Manual – SC8000
Right Side Scrub
The
Right Solution Solenoid Valve L11
controls the solution flow from the
Solution Pump M4
to the optional right
side scrub brush. Note that
L11
is not a proportional valve and is either on or off. The following conditions
must be met for solution to flow to the right side scrub brush:
•
The side scrub system must be installed and enabled.
• The
Driver Box
must receive a signal from the
Dashboard Panel
via the CAN Bus that the Operator has
enabled the main scrub and side scrub systems.
• The
Driver Box
must receive a signal from the
Drive Pedal Sensor R1
that the drive pedal has been moved
from the neutral position.
Fuse, 100A
Relay, Power
Dashboard Panel
Driver Box
K1
Battery
12 VDC
F1
Circuit Breaker, 15A
CB6
K1
B1
3
B
Relay, Power
J2-1
Ignition_KeyPos
J1-12
S1
Switch, Ignition
J1-3 CAN +
J1-2 CAN -
J6-3 CAN +
J6-1 (B+)
J6-2 (B-)
J6-4 CAN -
Twisted Pair
Twisted Pair
1
87
30
2
1
2
J1-10
J1-31
J1-11
1
3
2
Drive Pedal Sensor, 5K Ohm
R1
J3-2
J2-22
CB4
Circuit Breaker, 20A
CB5
Circuit Breaker, 10A
+
-
M4
M
Pump, Solution
Valve, Main Solution
L10
1
2
J1-21
Switch, Solution Empty (closes when the
solution tank is empty)
1
2
S3
Bat -
B- (ground)
Bat - (PWM)
J2-10
Valve, Right Solution
L11
1
2
Bat -
B+
Содержание sc8000
Страница 18: ...General Information 17 Service Manual SC8000 Overall Dimensions...
Страница 81: ...Wiring Diagram Kubota 1 6L LPG Engine 56107659 REV A Electrical System 80 Service Manual SC8000...
Страница 111: ...Hydraulic System 110 Service Manual SC8000 Hydraulic Schematic...
Страница 124: ...Hydraulic System 123 Service Manual SC8000 Special Tools Hydraulic test gauge w connector 3000 psi range p n 56504516...