Solution System 164
Service Manual – SC8000
Right Side Scrub Brush
On machines equipped
with the optional
Right Side
Scrub Brush
, the solution is
plumbed from the solution
system to the
Right Solution
Solenoid Valve
(L11). The
Right Solution Solenoid
Valve
opens along with the
Main Solution Solenoid Valve
(L10) to allow solution flow
to the nozzle at the
Right
Side Scrub Brush
.
Wash Hose
The optional wash hose kit
uses a separate
Wand Pump
(M8) to pump solution
from the solution tank to
the hose and
Wash Hose
Nozzle
located behind
the Operator seat. The
wash hose kit operates
independently and does
not require the Operator to
actuate the seat switch.
A pressure switch on the
Wand Pump
will switch on
the
Wand Pump
when the
Wash Hose Nozzle
is opened
and the solution pressure
in the hose drops below 40
psi. When the
Wash Hose
Nozzle
is closed and the
solution pressure in the
hose reaches 60 psi, the
pressure switch will switch
the
Wand Pump
off.
Right
Solution
Solenoid
Valve
Right
Side
Scrub
Brush
Main
Solution
Solenoid
Valve
Wash
Hose
Nozzle
Wand
Pump
Содержание sc8000
Страница 18: ...General Information 17 Service Manual SC8000 Overall Dimensions...
Страница 81: ...Wiring Diagram Kubota 1 6L LPG Engine 56107659 REV A Electrical System 80 Service Manual SC8000...
Страница 111: ...Hydraulic System 110 Service Manual SC8000 Hydraulic Schematic...
Страница 124: ...Hydraulic System 123 Service Manual SC8000 Special Tools Hydraulic test gauge w connector 3000 psi range p n 56504516...