Scrub System, Right Side 156
Service Manual – SC8000
Maintenance and Adjustments
Warning! Before performing any machine maintenance or adjustments, make sure the key
switch is off, the key is removed from the machine and the parking brake is engaged.
Side Brush Tilt Adjustment
1. Disconnect one of the two
Rod Ends
from its
Mounting
Tab
.
2. Loosen the
Jam Nut
.
3. Rotate either
Rod End
to lengthen or shorten the
Rod
End Assembly
as necessary to get the correct brush
angle to the floor.
Note:
The nominal factory dimension between
the Rod End stud centers is 7.5” ±.06”
[190.5 mm ±1.5 mm].
4. Make sure the threaded stud on the
Rod End
will
align with the matching hole in the
Mounting Tab
,
then tighten the
Jam Nut
.
5. Reinstall the
Rod End
into the
Mounting Tab
.
6. Run the brush up and down to check for correct brush
angle with the floor.
7. Repeat steps 1 through 5 above as necessary.
Rod End
Mounting
Tab
Jam Nut
Rod
End
Mounting
Tab
Rod End
Assembly