Scrub System, Cylindrical 146
Service Manual – SC8000
Main Scrub Deck and Right Side Scrub Down
The following conditions must be met for the Main Scrub Deck to move to the scrub (down) position:
• The
Key Switch
must be on.
• The engine must be running.
• The scrub on mode must be selected on the
Dashboard Panel
.
Component
Current - Amps
Coil Resistance - Ohms
L5
2.1 Amps
2.2 ohms
L6
1.5 Amps
8 ohms
L9
1.5 Amps
8 ohms
12VDC
12VDC
0V
L6
B-
B+ from
K1 Power Relay
(12V DC)
B- OUTPUT
TOUCH PAD
DASHBOARD PANEL
CB4
20A
ORN
B+
B-
RED/VIO
DRIVER BOX
PIN J2-26
MAIN SCRUB LIFT
CYLINDER DOWN
WHT/VIO
SCRUB CYLINDER
LOCK
PIN J2-4
YEL/BLU
B- OUTPUT
L5
S1
KEY SWITCH
B1
L9