![Michco sc8000 Скачать руководство пользователя страница 177](http://html1.mh-extra.com/html/michco/sc8000/sc8000_service-manual_1784517177.webp)
Solution System 176
Service Manual – SC8000
2.
After you rotate the
Plastic Nozzle Adapter
, make sure the
Brass Nozzle Adapter
is holding the
Plastic
Nozzle Adapter
securely in the
Spray Nozzle Bracket
. Tighten the
Brass Nozzle Adapter
to the
Plastic Nozzle
Adapter
as necessary.
Detergent System Maintenance
You will need to purge the system of the previous detergent when switching to a different detergent.
Service Note:
Move the machine over a floor drain before purging because a small amount of
detergent will be dispensed in the process.
To Purge When Changing Detergents (the scrub system must be off)
1.
Disconnect and remove the detergent cartridge.
2.
Turn the key switch on and wait a few seconds for the start-up sequence to finish.
3. Press and hold the detergent switch for approximately two seconds.
4.
Release the switch when the detergent
Purge Icon
appears on the display and the detergent indicator
starts flashing.
Note:
Once activated, the purge process takes at least 10 seconds for AXP
™
/EDS systems, and at
least 20 seconds for EcoFlex
™
systems. Normally one purge cycle is adequate to purge the
system.
Purge
Icon
Содержание sc8000
Страница 18: ...General Information 17 Service Manual SC8000 Overall Dimensions...
Страница 81: ...Wiring Diagram Kubota 1 6L LPG Engine 56107659 REV A Electrical System 80 Service Manual SC8000...
Страница 111: ...Hydraulic System 110 Service Manual SC8000 Hydraulic Schematic...
Страница 124: ...Hydraulic System 123 Service Manual SC8000 Special Tools Hydraulic test gauge w connector 3000 psi range p n 56504516...