MHS Boilers Ltd ©
191007
7
1.4 Service
For commissioning and assistance in maintenance matters, please contact the Technical Services
Department via 01268 546700.
1.5 General restrictions
MHS Boilers Ltd products should always be used, installed and maintained in accordance with the
statutory requirements, specifications and standards applicable to these installations.
All the data, information and suggestions concerning its products provided by MHS Boilers Ltd are
based on careful study.
However, the use, installation and operation of the same are outside the control of MHS Boilers Ltd
and neither MHS Boilers Ltd nor any other organisations associated with it, accept any liability for the
same.
Changes may be incorporated without prior notice. MHS Boilers Ltd accepts no obligation to
adapt previously delivered products to incorporate such changes.
2 Description
2.1 General
All WM wall mounted boilers are environmentally friendly gas fired heating boilers with a modulation
range between approximately 20% and 100% of their maximum output.
The WM series consists of 5 models of boiler with an output range of 45 to 120 kW. The appliances
have low NO
x
and CO emission, which satisfy the most stringent environmental requirements.
The WM series has received CE Approval for all relevant European countries and has been registered
under the Product Identification Number 0063BO3192.
The boilers may be used on both open (category B23) as well as room sealed (category C13, C33,
C43, C53, C63 or C83) systems.
As standard, the boiler is delivered fully wired, fully assembled, and tested.
Working principle and design
Air is drawn in as required, via a speed controlled fan. The zero pressure controller of the gas valve
measures the under pressure in the venturi and modulates the gas in response to this pressure
from the fan. The gas/air is then thoroughly mixed in the correct ratio and passed directly into
the burner.
A temperature controller compares the actual water flow temperature to the desired water
temperature.
The controller interprets the load required and adjusts the fan speed. The fan sends a
speed feed-back signal, and the controller re-adjusts the speed as required.
The mixture of gas and air that is formed is then conveyed through the cylindrical stainless steel
burner for combustion.
The heat exchange takes place in a double heat exchanger block. The first heat exchanger is located
immediately next to the burner, while the second heat exchanger is connected downstream