80
PARAMETERS
4.2.9
Load pattern selection (Pr. 14)
Pr. 14 "load pattern selection"
You can select the optimum output characteristic (V/F characteristic) for the application
and load characteristics.
Parameter
Number
Factory
Setting
Setting
Range
14
0
0 to 3
Note:1. This parameter setting is ignored when the general-purpose magnetic flux
vector control mode has been selected.
2. Pr. 46 "second torque boost" is made valid when the RT signal turns on.
The RT signal acts as the second function selection signal and makes the
other second functions valid.
Refer to page 147 for Pr. 180 to Pr. 183 (input terminal function selection).
Pr. 0 "torque boost"
Pr. 46 "second torque boost"
Pr. 80 "motor capacity"
Pr. 180 to Pr. 183
(input terminal function
selection)
Related parameters
100%
Pr.14=0
For constant-torque loads
(e.g. conveyor, cart)
Output
voltage
Base frequency
Output frequency (Hz)
Pr.14=1
100%
Output
voltage
Base frequency
Output frequency (Hz)
For variable-torque loads
(Fan, pump)
Pr.0
Pr.46
Pr.14=2
100%
Output
voltage
Base frequency
Output frequency (Hz)
For lift
Boost for forward rotation...Pr. 0 (Pr.46) setting
Boost for reverse rotation...0%
Forward
rotation
Reverse
rotation
Pr.0
Pr.46
Pr.14=3
100%
Output
voltage
Base frequency
Output frequency (Hz)
For lift
Boost for forward rotation...0%
Boost for reverse rotation...Pr. 0 (Pr.46) setting
Reverse
rotation
Forward
rotation
M4500E.book 80 ページ 2005年2月22日 火曜日 午後5時7分
Содержание M4000E series
Страница 11: ...MEMO ...
Страница 23: ...12 MEMO ...
Страница 55: ...44 MEMO ...
Страница 173: ...162 MEMO ...
Страница 199: ...188 MEMO ...