159
4
PARAMETERS
(3) Read Pr. 903 and show the current setting of the gain frequency.
(Pr. 902, Pr. 904 and Pr. 905 can also be adjusted similarly.)
(4) Set a gain frequency in Pr. 903 and show the analog voltage value across
terminals 2-5 in % (when the frequency is set to 80Hz)
MODE
SET
REV
STOP
RESET
FWD
PU
EXT
MON
Hz RUN
A
SET
0 to 9
0 to 9
PU
EXT
Hz
RUN
A
Most significant
digit flickers.
Middle digit
flickers.
Least significant
digit flickers.
Current setting of gain frequency
SET
SET
SET
Parameter setting mode
MODE
Using the key, choose the
"parameter setting mode" as in (2)-1).
×
9 times
×
3 times
Press for 1.5s
SET
PU
EXT
Hz
RUN
A
PU
EXT
MON
Hz
RUN
A
PU
EXT
MON
Hz RUN
A
Current setting of
gain frequency
Changing the gain
frequency
Press to change
the set frequency.
Analog voltage value (%)
across terminals 2-5
In any of the methods in (5)-1) to (5)-3) on the following
page, continue the setting until the analog voltage value
flickers. If you end the setting here, the gain frequency
change will not be reflected.
M4500E.book 159 ページ 2005年2月22日 火曜日 午後5時7分