104
PARAMETERS
4.2.26 Applied motor (Pr. 71)
Pr. 71 "applied motor"
Set the motor used.
•
When using the constant-torque motor,
set "1" in Pr. 71 for either V/F control or
general-purpose magnetic flux vector
control.
The electronic thermal relay function is
set to the thermal characteristic of the constant-torque motor.
•
When you selected the constant-torque motor, the values of the following parameters
are automatically changed. (only for the factory setting value)
Pr. 0 "torque boost", Pr. 12 "DC injection brake voltage"
<Setting>
•
Refer to the following list and set this parameter according to the motor used.
By setting any of "100 to 123", thermal characteristic of electronic thermal relay function
(applied motor) can be changed as indicated below according to the ON/OFF status of
the RT signal:
Parameter
Number
Factory
Setting
Setting Range
71
0
0, 1, 3, 5, 6, 13, 15, 16, 23, 100, 101, 103,
105, 106, 113, 115, 116, 123
Pr. 71
Setting
Thermal Characteristics of Electronic
Thermal Relay Function
Applied motor
Standard
Constant-
Torque
0, 100
Thermal characteristics of a standard motor
1, 101
Thermal characteristics of a constant-torque motor
3, 103
Standard motor
Select "offline auto tuning
setting".
13, 113 Constant-torque motor
23, 123 Do not set.
5, 105
Standard motor
Star
connection
Motor
constants can
be entered
directly.
15, 115 Constant-torque motor
6, 106
Standard motor
Delta
connection
16, 116 Constant-torque motor
RT Signal
Thermal Characteristic of Electronic Thermal Relay Function (Applied Motor)
OFF
As indicated in the above table
ON
Constant-torque motor
CAUTION
Set this parameter correctly according to the motor used.
Incorrect setting may cause the motor to overheat and burn.
Set the electronic thermal relay function to the thermal characteristic for the
constant-torque motor when using a geared motor (GM-G, GM-D, GM-SY,
GM-HY2 series) to perform general-purpose magnetic-flux vector control.
Pr. 0 "torque boost"
Pr. 12 "DC injection brake voltage"
Pr. 19 "base frequency voltage"
Pr. 80 "motor capacity"
Pr. 96 "auto-tuning setting/status"
Related parameters
M4500E.book 104 ページ 2005年2月22日 火曜日 午後5時7分
Содержание M4000E series
Страница 11: ...MEMO ...
Страница 23: ...12 MEMO ...
Страница 55: ...44 MEMO ...
Страница 173: ...162 MEMO ...
Страница 199: ...188 MEMO ...