C
ompressed-air Stapling Plier
Z 23 P
Page:
11
Mod.:
01/2022
ET
Seite 11 von 34 31.01.22 P:\Technik\ZANGEN\Z 23 P\Bedienungsanleitung\Englisch\Manual Z 23 P Pneum en_01_2022.docx
In order to maintain the operational readiness and function of the stapler, it must be regularly
checked, serviced and cleaned by the operator or/and by qualified personnel.
Test area
Activity /
examination
T W M
J
Area
Stapling device
Clean/check
prüfen
⚫
Stapling area
Stapling device
Clean and
lightly oil
⚫
Stapling area
Clean/check
⚫
Pneumatic hoses, tightness,
Damage
check
⚫
Pneumatic
Check screw connections for tight
fit
check
⚫
Filter regulator
clean /
drain
⚫
T = daily / W = weekly / M = monthly (6M = alle 6 Monate) / yJ = yearly
•
All friction points/movable parts should be lightly oiled from time to time.
•
Do not use aggressive cleaning agents or solvents (damage seals) or abrasive media used for
cleaning.
•
Cleaning with compressed air is also to be avoided as there are dirt particles get into the
sealing areas and damage them.
•
Do not use foot wash for cleaning.
•
Soiling must be removed directly from the operator after machining operations.
The following work / inspections should be carried out regularly by qualified personnel:
•
Regularly oil the moving parts (no graphite oil!) (Weekly)
•
Check the filter regulator for condensation. The condensation water may have to be
removed.
Only ORIGINAL spare parts may be used.
(see “spare parts list”)
In case no ORIGINAL spare parts are used each warranty claim, or any liability
is excluded!
All technical equipment, especially the safety equipment, must be checked
regularly by specialists, especially after repairs.