C
ompressed-air Stapling Plier
Z 23 P
Page:
10
Mod.:
01/2022
ET
Seite 10 von 34 31.01.22 P:\Technik\ZANGEN\Z 23 P\Bedienungsanleitung\Englisch\Manual Z 23 P Pneum en_01_2022.docx
Never staple without stapling material. Do not remove the stapler until the stapling process is
complete.
Do not staple in hard or brittle materials or on a hard surface
If a stapling fault occurs, clear it immediately and do not initiate any
further stapling
Turn off the stapler after use
If possible, the stapler should be hung above the packing station.
The following accessories are available:
B 2/4 balancer (weight equalizer) with rotatable load hook
DS DS 75 spiral hose with an extended length of 7.5 m
Filter regulator
W / UNIT maintenance unit
consisting of pressure reducer, water separator, oil nebuliser
9
Shutting down
In case the tool will not be handled for some time, please disconnect the air pressure and
remove all staples.
10
Maintenance and care
ATTENTION!
Before every maintenance, the compressed air supply must be
removed.
Only original spare parts from the manufacturer are to be used
(see appendix "Spare parts list").
Any kind of alteration to the device (e.g. drilling of holes) is only permitted
with prior consent and written permission of the manufacturer.
Manipulation of the safety device(s) is prohibited.