C
ompressed-air Stapling Plier
Z 23 P
Page:
27
Mod.:
01/2022
ET
Seite 27 von 34 31.01.22 P:\Technik\ZANGEN\Z 23 P\Bedienungsanleitung\Englisch\Manual Z 23 P Pneum en_01_2022.docx
16.1.2
Heavy soiling
Wipe down the housing of the stapling device with a cloth that has been slightly dampened
with mild soap solution.
Then wipe down the housing with a cloth that has been slightly dampened with tap water.
Dry it off with a soft, dry cloth.
Oil all metal parts of the stapling device with a thin layer of special oil.
16.2
Oiling the stapling device
ATTENTION
Insufficient lubrication, or use of incorrect lubricants, can cause damage to the stapling
device.
Use only special oil.
If there is no oiler installed, and the length of the air line to the stapling device is
over 10 m, sufficient lubrication is not guaranteed.
In these two cases, add two to five drops of special oil directly into the compressed air
connector every day before starting operation.
ATTENTION
If the oil spills, there is a risk of environmental damage.
Bind the spilled oil with a binding agent.
Wipe up bound oil with rags.
Dispose of the rags in accordance with the applicable legal regulations at the site.
17
Faults
In the event of a fault that goes beyond jammed brackets, please contact
us. The stapler is carefully examined by our specialists and the
malfunction is rectified.
WARNING
Operating a damaged or faulted stapling device can cause severe or fatal
injury.
Disconnect the stapling device from the compressed air supply in case of
fault.
Empty the magazine.
Do not use the stapling device until the fault has been corrected.