6
Technical Data
page 53
ELC X-Series-V1.3-09.16-GB
subject to technical alterations
6.4 ELC X12, X12i, X12B
Output power characteristics
Type
ELC X12-110
ELC X12i-110
ELC X12B-110
Power factor
Typ. 0.99
Typ. 0.99
Typ. 0.99
Power efficiency
> 0.96
> 0.96
> 0.96
Nominal power range
2400 W – 12000 W
2400 W – 12000 W
2400 W – 12000 W
Electrical characteristics
Type
ELC X12-110
ELC X12i-110
ELC X12B-110
Nominal supply voltage
400 V - 480 V
400 V - 480 V
400 V - 480 V
Nominal supply current
32 A – 27 A
32 A – 27 A
32 A – 27 A
Max. supply current
36 A
36 A
36 A
Line protection*
min. 40 A
min. 40 A
min. 40 A
Mains frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Min. mains voltage (shut down
voltage)
320V
320V
320V
Output power reduction in case
of low mains voltage
from approx. 360V –
320V:
25 W/V
from approx. 360V –
320V:
25 W/V
from approx. 360V –
320V:
25 W/V
Abs. max. mains voltage
528V
528V
528V
Leakage current
12.5 mA
12.5 mA
12.5 mA
Insulation resistance between
primary and PE
>30 M
Ω
>30 M
Ω
>30 M
Ω
Discharching time of residual
voltage after mains
disconnection
25min
25min
25min
Charge time (minimum time
between switch on of the ELC
and starting the lamp)
12 s
12 s
12 s
*Line protection: automatic cut-out characteristic C
Lamp characteristics
Type
ELC X12-110
ELC X12i-110
ELC X12B-110
Nominal lamp power
12 kW
Nominal lamp voltage
1000V - 1100V
Tolerance lamp voltage
nominal voltage ± 5 %
Threshold voltage of {lamp
voltage low} warning bit
700 V
Ignition voltage / period
approx. 2800 Vpk / 700 ms, 5 trials