3
Installation
page 27
ELC X-Series-V1.3-09.16-GB
subject to technical alterations
PROFIBUS-output-data (Master
→
ELC)
Byte-
No.
0
1
2
3
4
5
Name
[Power
Set
Value]
[Installed
Lamp
Power]
[Lamp
Control]
[Reserved]
To limit the maximum output power, use the register
[Installed Lamp Power]
(see Fig. 15).
This function is appropriate if the nominal power of the lamp is lower than the nominal power
of the ELC.
Fig. 15: Limited output power characteristic, showing the dimming range of X6 (for the dimming range
of other power classes see chapter 6)
The control characteristic of Fig. 14 comes into effect, if the register
[Installed
Lamp Power]
is
•
not set
•
below minimum dimming range (given in % of ELC nominal power in
chapter 6)
•
above ELC nominal power
Sollleistungs-
vorgabe
[Power Set
Value]
Lamp power
[Installed Lamp
Power]
ELC-nominal-
power
14% ELC-nominal-power
14% ELC-nominal-power
Installed lamp
power
[Power Set
Value]
ELC-nominal-
power
Sollleistungs-
vorgabe
[Power Set
Value]
Lamp power
[Installed Lamp
Power]
ELC-nominal-
power
14% ELC-nominal-power
14% ELC-nominal-power
Installed lamp
power
[Power Set
Value]
ELC-nominal-
power
☞