Lamp feeder cable: approved types and lengths
The use of cable types which have not been approved by the manufacturer
can lead to malfunction. The possibility of damage to the electronic ballast
cannot be excluded.
Type
ELC X4-40
ELC X4B-40
Article no. 8092
U
0
/U = 0.8/1.4kV
2x2.5 mm²
Ø 9.3 mm
UL AWM Style 21179
2-40 m
2-40 m
Article no. 8044
U
0
/U = 0.6/1kV
2x2.5 mm²
Ø 9.8 mm
GL-approved
2-40 m
2-40 m
Article no. 8045*
U
0
/U = 1.8/3kV
2x4mm²
OD-Ø 16.9mm
GL-approved
on request
on request
The data refers to the distance between ELC and lamp.
* This cable cannot be connected directly to the ELC due to the diameter.
Mechanical characteristics
Type
ELC X4-40
ELC X4B-40
Dimensions
(approx. H x W x D)
125 x 470 x 260 mm
125 x 470 x 260 mm
Weight (approx.)
11kg
on request
Installation position
vertical or horizontal as described in 3.1
☞