
6
Technical Data
page 49
ELC X-Series-V1.3-09.16-GB
subject to technical alterations
Control characteristics
Type
ELC X6-60
ELC X6B-60
ELC X6i-60
Current requirement of 24V-
supply (X805.5)
2.2A max. for ELC control circuitry
Output currents of X806 Pins 5 + 6 have to be
added
2.7A
Output currents of X806
Pins 5 + 6 have to be
added
Baud rate
PROFIBUS: 500kBit
MODBUS: Baud rate 19200, 8 Databits, Even parity, 1 Start/Stop Bit
Ambient conditions
Type
ELC X6-60
ELC X6B-60
ELC X6i-60
Humidity
Max. 85%, non-
condensing
Max. 95%
Max. 85%, non-
condensing
Ambient operation temperature
5°C to +45°C
5°C to +55°C
5°C to +45°C
Ambient storage temperature
-20°C to +70°C during storage and transportation, before initial operation
leave at least 4 hrs at room temperature
Maximum storage period
2 years (also see chapter 4.2)
Air flow
max. 200 m³ / h at T
A
>35°C
Typ. 100 m³ / h
Altitude of site
Max. 4000m NN
Up to 2000m NN without derating
2000m NN to 4000m NN: 1.5% / 100m power reduction effected by ELC-
control (example: X6= 4200 W at 4000m NN)
Certification
Type
ELC X6-60
ELC X6B-60
ELC X6i-60
Protection
IP 54
Protection of front fan IP x4
Note: protection is only guaranteed if cables of the given diameters are
used (see chapter 3.2.2)
EMC
EN 55011
EN 61000-3-3
EN 61000-6-2
Safety
EN 50178
Marine approvals
- -
GL (pending)
- -