Slurry Pump
WH15AM1AAA0EN_06B.DOC
JAN
05-W02
Operation
1/2
8
OPERATING INSTRUCTIONS
8.1 Start-up
1.
If the pump has just been maintained or has not been put into operation for some
time, then carry out the pre-start checks as described in Commissioning, section 7.
2.
Open the pump inlet and outlet valves.
3.
Check for leakage from the inlet and outlet connections.
NOTE
:
AN INLET
-
SIDE LEAK MAY CAUSE THE PUMP TO DRAW AIR DURING OPERATION
,
THUS
DRASTICALLY REDUCING ITS PUMPING CAPACITY
.
4.
If a water flushed gland is fitted, ensure that the water supply is turned on, and water
is available at the correct pressure and flow rate.
5.
If a mechanical seal is fitted, see section 9.5.3 before start up.
6.
If auxiliary priming equipment is fitted, start the priming pump.
7.
Start the pump drive motor.
8.2 Shutting
down
The appropriate shutdown procedure for any installation depends on the slurry being
pumped, and more generally on the process requirements upstream and downstream of
the pump. What follows, therefore, may only be regarded as general guidelines for
ensuring some degree of protection for the pump without reference to the particular
application.
•
Where practicable, switch the pump to clean water and allow the pipeline to be flushed
through before shutting down.
•
In case of systems with substantial discharge pipework and/or head of slurry, means of
isolating the pump or draining the system should be provided –see section 6.5.
CAUTION
STOPPING THE PUMP WHEN THERE IS A HEAD OF SLURRY IN THE DISCHARGE PIPE SHOULD BE
AVOIDED AS THIS COULD RESULT IN DAMAGE TO THE GLAND AND
/
OR PUMP
.
•
Having shut down the pump on clean water, close its isolating valves and then drain
the pump and its pipework, if required.
CAUTION
ALWAYS
CLOSE THE OUTLET VALVE FIRST
.
NEVER
CLOSE THE INLET VALVE WHILE THE PUMP IS
RUNNING
.
NOTE
:
REVERSE FLOW
,
IN ADDITION TO POSING A RISK OF DAMAGE TO THE SHAFT SEAL
,
CAN ALSO
CAUSE THE IMPELLER TO SPIN IN THE REVERSE DIRECTION
.
STARTING THE PUMP UNDER
THESE CONDITIONS MIGHT CAUSE DAMAGE TO A MECHANICAL SEAL
,
IF FITTED
,
AND
/
OR CAN
IN EXTREME CASES CAUSE THE SHAFT TO SHEAR
.
AN OVERRIDE CIRCUIT IS RECOMMENDED
TO PREVENT THE PUMP BEING STARTED INADVERTENTLY WHILE THE IMPELLER IS ROTATING
.
Содержание 25411801001/A5684
Страница 18: ...25411801000 ...
Страница 19: ...25411801000 ...
Страница 28: ...Slurry Pump WH14AAAAAA0EN_04D DOC JAN 04 W08 Control system 1 1 5 CONTROL SYSTEM NOT APPLICABLE ...
Страница 76: ...Slurry Pump WH24AAAAAA0EN_03B DOC JAN 04 W08 Spare parts 1 1 10 4 Spare part drawing ...
Страница 77: ...Slurry Pump WH24AM1W010XX_02E DOC JAN 04 W08 Spare parts 1 1 W3 W2 W4 W1 W6 F3 F4 F1 F2 W17 W19 W20 W21 W18 ...
Страница 84: ...Slurry Pump WH26MM1AAA0EN_03C DOC JAN 04 W08 Appendices 3 2 11 2 Reference publications ...