15.6.2012
Rev. 1.7
Installation
36
5.3.1 Electrical connection
Connections are to be done according to the installation drawing and the electric diagram.
The kettle is equipped with a decoupling switch, which separates the kettle totally from
the electrical network.
5.3.2 Water connection
The water connection is to be done according to the installation drawing. Connections to
the water tap are to be fitted with one-way and shut-off valves (not included in delivery).
The cold water connection is of size Ø 15 mm (G 1/2”) and the warm water connection of
size Ø 10 mm (G 3/8”).
5.3.3 Steam and condensate connections
The steam and condensate connections of the Culino combi-kettle must be carried out by
a person with professional competence in the field. Improper connections and piping may
severely impact the correct function of the kettle.
The location of the steam and condensate connection points appears from the installation
drawing.
The maximum steam pressure in the kettle is 1 bar. The steam supply line must be fitted
with a one-way valve, a shut-off valve, a filter, a pressure reduction valve and a safety
valve set at 1,5 bar.
The condensate pipe must be on the same floor as the kettle or go to the floor below. Lead-
ing the condensate pipe to the floor above the kettle is not allowed, as it creates a water
trap that prevents normal function of the kettle.
The condensate pipe must be free from pressure created by other appliances.
5.4 Ventilation
The heat and steam load of the kettle must be taken into account in the kitchen's ventila-
tion plan. A ventilation hood must be installed above the kettle, because plenty of steam
is released when the kettle lid is opened. When dimensioning the ventilation hood, the
space requirement for opening the lid must be taken into account (see installation draw-
ing).
5.5 Other installations
In case the combi-kettle being installed is provided with a self-control option (HACCP),
and it is taken into use, the data cabling and the installation of the program must be carried
out according to separate instructions.
Содержание Culino Combi 40S
Страница 2: ......
Страница 4: ...15 6 2012 Rev 1 7...
Страница 50: ...15 6 2012 Rev 1 7 Troubleshooting 44...
Страница 52: ...Installation drawing L00133 C3...
Страница 53: ...Installation dimensions K02450 A3...
Страница 54: ...Text L00134 B4...
Страница 55: ...Steam supply recommendations 000030 A4...
Страница 58: ......