Operating instructions
11
4.1.5 Yearly
•
It is advisable to have the unit checked once a year by qualified personnel. Preven-
tive checking is the best guarantee for operational reliability and saves breakdown
costs.
Fill out the form “Notes on service work” with information on service work which has
been done according to the instructions. Maintenance work ensures the safe and reliable
function of the kettle.
4.1.6 Emptying of surplus condensate water
It is not allowed to open the emptying valve of the kettle jacket, if the temperature of the
steam jacket of the kettle is over +100°C. Watch out for releasing hot steam and water
when you open the above mentioned valve.
1. emptying valve of kettle jacket
•
Check that the kettle is in its upright position.
•
Open the emptying valve by turning the handle downwards.
The kettle does not heat, if there is a lot of surplus condensate water or undrained cooling
water in the kettle jacket.
4.1.7 Total emptying of the kettle jacket
It is not allowed to open the emptying valve of the kettle jacket, if the temperature of the
steam jacket of the kettle is over +100°C. Watch out for releasing hot steam and water
when you open the above mentioned valve.
1.
Open the emptying valve.
2.
Tilt the kettle approximately 45°.
3.
When water stops to flow out, tilt the kettle slightly forwards and backwards until
water no longer flows out.
4.
Return the kettle to the cooking position.
Содержание Culino Combi 40S
Страница 2: ......
Страница 4: ...15 6 2012 Rev 1 7...
Страница 50: ...15 6 2012 Rev 1 7 Troubleshooting 44...
Страница 52: ...Installation drawing L00133 C3...
Страница 53: ...Installation dimensions K02450 A3...
Страница 54: ...Text L00134 B4...
Страница 55: ...Steam supply recommendations 000030 A4...
Страница 58: ......