![MERRICK MC3 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/merrick/mc3/mc3_operation-and-maintenance-manual_1774863050.webp)
MC³ 24.96.EX O&M Manual
Page 42
08/14/01 4:34 PM/LDD
Logical Output
Description
Manual Setpoint
The Feedrate Setpoint Mode is “Man Spd”. See Feedrate
setpoint on page 16.
Z Tracking High
The Zero Tracking load has stepped out of the load limit. See
Zero Tracking Parameters on page 28.
PID off Limits
The output from the PID controller algorithm is greater than
99.995% or is less than .005%. See PID Parameters & Output
Dynamic Protection on page 25.
Master Com Lost
Communications has timed out. See Communication Time-out
on page 45.
Belt Slippage
The two tachos do not comply. See Tachometer Parameters
on page 29.
Always On
Output is always ON ( closed ).
Always Off
Output is always OFF ( open ).
Restr. Access
Indicates restricted access to registers for communications
and the register editor. See also the “Extended Access” logical
input in List of Logical Inputs on page 37.
In Menu System
The controller is in one of the SET or ACT menus.
High Speed Limit
The belt speed is above the High Speed limit. See Limit
Switches on page 26. Action is delayed according to the High
Speed Delay parameter.
Low Speed Limit
The belt speed is below the Low Speed limit. See Limit
Switches on page 26. Action is delayed according to the Low
Speed Delay parameter.
Discharge Gate
This output is used to control the discharge, ahead of the
feeder, gate for batching.
Batch Running
On when a batch in running.
Batch Pause
On when the batch has been paused.
Batch Complete
On when the batch has been completed.
Batch Error
On when there has been an error in the batch process, either a
time-out or a batch under- or overweight. See Batch
Parameters on page 15
Serial Setpoint
The Feedrate Setpoint Mode is “RM Serial”. See Feedrate
setpoint on page 16.
AIN1 High Alarm
No useful function. Do not use.
AIN1 Low Alarm
No useful function. Do not use.
AIN2 High Alarm
No useful function. Do not use.
AIN2 Low Alarm
No useful function. Do not use.
Inferred Speed
The speed used by the controller is inferred, either because
the tacho mode is set to Simulator, or Auto-Bypass mode and
there is a tacho discrepancy condition. See Tachometer
Parameters on page 29.
List of Physical Outputs
Physical Output
Description