![MERRICK MC3 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/merrick/mc3/mc3_operation-and-maintenance-manual_1774863023.webp)
MC³ 24.96.EX O&M Manual
Page 15
08/14/01 4:34 PM/LDD
SETPOINT
Various screens may be displayed based on the mode of your controller.
Setpoint Screens
These are the screens you will see when batching and PID logical inputs are turned on. You are
able to toggle between the two screens by touching the
or
buttons.
Batch setpoint
If the PID is turned off and Batching is enabled this is the setpoint screen you will see.
There are two Batch setpoint methods available in this controller.
Local
Remote Serial
Local
When this mode is selected, the batch setpoint is entered by the operator at the
controller. This setpoint is in engineering units for total.
Remote Serial
This setpoint mode allows the MC³ Controller to receive a batch setpoint from a remote
device through the serial port such as a computer or a PLC/SuperBridge Controller.
This method requires that the remote device is connected to the controller via the RS-
485 serial port.
NOTE:
When the controller is to be used in SuperBridge or any other system which transmits setpoint
information using Serial Communications, the Remote Serial mode must be selected. The rules and
format of the data exchange is described in [1].
Setpoint
This button allows you to directly edit the batch setpoint using a numeric edit screen.
Batch Parameters
This button allows you to edit the batch parameters.
LC-Head Length This parameter is the length from weigh idler to the head pulley (where material
drops off the end of the belt).