![MERRICK MC3 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/merrick/mc3/mc3_operation-and-maintenance-manual_1774863030.webp)
MC³ 24.96.EX O&M Manual
Page 22
08/14/01 4:34 PM/LDD
Five seconds are allotted to allow the belt to start to spin up for the tacho type and direction
detection. Next the speed calibration procedure is performed. This procedure determines the
number of tacho pulses per belt revolution.
NOTE:
The belt must cycle the number of revolutions that is indicated on the speed calibration screen.
Touch
when you are ready for the test to be performed. Allow the number of revolutions
specified by # Speed Revs (page 28) to accumulate then touch
. If value is reasonable,
touch
. The speed will automatically increase to determine the design speed of the
feeder. When this speed is found, the controller will stop the feeder.
WARNING: THE BELT WILL START MOVING TO COMPLETE THIS TEST.
Next the zero procedure will be run to determine the zero load value for your feeder. After touching
the controller will take 5 seconds to allow the feeder to spin up for the test. Touch
to begin the procedure. This will zero the controller when there is no load on the feeder.
Touch
to accept results.
WARNING: THE BELT WILL START MOVING TO COMPLETE THIS TEST.
Next the chain calibration procedure will be performed. You must put the test chain on the
controller. The controller will run 30 seconds to allow the load to stabilize before allowing the
procedure to be run. Touch
to start the procedure. Touch
to accept results.
Touch
to accept results and quit EZ Setup.
WEIGHT EZ SETUP
This procedure assumes:
1. All Electrical connections and wirings are correct.
2. Acceptance of factory default settings.
3. Belt Length, Maximum Feedrate and the Static Calibration Weight values are known.
4. You have test weights available for the procedure.
The Calibration Speed (page 31), number of speed calibration revolutions (# Speed Revs page 28)
and the number of calibration procedure revolutions (# Proc Revs page 28) may be adjusted for
your specific application by entering the custom setup menu and changing the value. See Entering
New Values on page 9 for the proper method to enter values into Numeric Entry Screens.
Touch
to enter the Units Select menu. Scroll to the array of units that is correct for your
application. Touch
to set the units.
Touch
to enter the numeric entry screen for the “EZ Setup” parameters. You will need
to know the maximum feedrate for the feeder, the length of the belt and the calibration weight. See