MC³ 24.96.EX O&M Manual
Page 11
08/14/01 4:34 PM/LDD
Blank Button
This button places a empty line on the screen.
Setpoint
Based on the mode of the controller this button will allow you to enter the Batch or Feedrate
setpoint. If the mode is Batching Feeder both Batch and Feedrate setpoint methods are available
from this button. See Setpoint on page 15 for more information.
LOGO
This screen displays the address and phone number for Merrick.
It also shows the revision and build date for the software that is currently in operation. The version
and build date are important when you need service on your controller.
Start, Stop, Clear Batch
These buttons allow you to start, stop, or clear a batch. The buttons will only be visible
when Batch Controls is enabled. See Digital Inputs Setup on page 36. The batch will run until the
batch total has reached the batch setpoint, and the load has dropped below 3% of the design load.
Start batch starts a batch process. It will turn on the Discharge Gate logical output.
When the batch total has reached the batch setpoint minus the Preact value has been
reached, the Discharge Gate logical output will turn off. (see Batch Parameters on page
15 for more information).
Stop batch pauses a batch process. It will turn off the Discharge Gate logical output.
The batch may be restarted by touching the start batch button. The batch may also be
cleared by touching the clear batch button.
Clear Batch stops the current batch process clears the batch total and turns off the
Discharge gate logical output.
Indicators ( on Feeder Screen)
There are indicators which are used by the software to provide you with a visual
indication that the controller is operating properly. The operator can insure that the
controller is in the correct mode and accomplishing its set tasks by being aware of which
visual indicators are (ON) or (OFF).
HI
High Feedrate - This indicator is on when a high feedrate condition exists.
The type and value of High Limit Switch is determined by the operator. When
this indicator is off the feedrate is not above the parameters set in Limit