![MERRICK MC3 90.10.EX Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/merrick/mc3-90-10-ex/mc3-90-10-ex_operation-and-maintanance-manual_1774865051.webp)
MC³ 90.10.EX O&M Manual
- 44 -
LED #
Desc
3/C
Com 1 Receive
4/D
Com 1 Transmit
5/E
Test Pin 1
6/F
Test Pin 2
7/G
Test Pin 3
8/H
Test Pin 4
9/I
Power Fail
10/J
Power ON
JTAG/SERVICE Port (J8)
Pin
Desc
1
+5VDC
2
Test Pin 1/LED 5/E
3
GND
4
Test Pin 2/LED 6/F
5
TCK
6
Test Pin 3/LED 7/G
7
TDO
8
Test Pin 4/LED 8/H
9
TDI
10
NMI (/Debug Break)
11
TMS
12
CPU Reset
13
TRST# (Nomal operation 13/14 are jumpered)
14
PWRGD (Nomal operation 13/14 are jumpered)
15
No Connection
16
Flash Lockout (see SW1)
Option Jumper Settings
Jumper
Desc
JP1
FLASH PROGRAMMING VOLTAGES
Strap 1 to 2 for +12VDC Flash Programming Voltage
Strap 2 to 3 for +5VDC Flash Programming Voltage
Default 2-3
Printer Operation
MC³ CPU board must be specifically configured for Printer operation. Call Merrick for details to
verify your CPU board configuration.
Backplane Board
Each Back plane board is termed a Rack in the MC³ controller. A standard controller consists of
one PCIO and one Back plane board. Up to four Back plane boards may be connected in a
cabinet using two PCIO boards.
Two different Back plane boards are available for use with Feeder systems. One is DC dry
contact input style with four inputs and seven outputs. The other is an AC input style with four
inputs and eight outputs.