MC³ 90.10.EX O&M Manual
- 16 -
acknowledgement that the value has been cleared the string
“SubTotal Cleared"
will be
displayed.
Total
– This is the Master Total for the feeder. This value cannot be cleared from this
controller. It must be cleared at the specific feeder.
If there are Warnings on the selected feeder, the
button will be displayed. The feeder
Warnings may be cleared by touching the
button. The string
"Clear Pending"
will be
displayed informing that the request is pending. When confirmation that the Warnings have been
cleared returns, the string "Warnings Cleared" will be displayed.
If there are Faults on the selected feeder, the
will be displayed. Any Faults must be cleared
at the specific feeder. If this button is pressed the string
"THE FAULTS CAN ONLY BE
CLEARED AT THE FEEDER!!”
will be displayed.
The bar graphs under each of the numeric displays are scaled to the respective Maximum values.
Feedrate and Setpoint are scaled to the Max Feedrate value (page 17). Weight/Load is scaled to
the Max Wt/Load value (page 17). The speed value is scaled to the Max Speed value (page 17).
Feeder Settings
The
and
buttons cycle through each of the available feeders. The
(heart rate)
indicator is used to confirm that communications is taking place and will toggle between and
.
If one of the indicators stays on for an inordinate amount of time, communications may have been
lost.
The first line displays the current feeder number and the associated string. In the example below,
it is Feeder 1 and the assigned name is Sand Bin 1 F1.
The second line displays the communication connection for the feeder. This feeder is attached to
Port 0, with a unit address of 1. These values are set in the numeric entry menu.
The next set of data is the units data used by the selected feeder. This controller uses the setting
to determine which conversion factors to use. This set of strings should be the same as on the
selected feeder. If unsure contact Merrick Industries to properly set this value.
The units button select the type of feeder that is connected (BELT, LIW or FMTR). The
button is used for Belt Feeder Controllers (ex. 20.10.EX). The
button is
used for Loss-In-Weight Controllers (ex. 30.00.EX or 30.10.EX). And the
for