![MERRICK MC3 90.10.EX Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/merrick/mc3-90-10-ex/mc3-90-10-ex_operation-and-maintanance-manual_1774865019.webp)
MC³ 90.10.EX O&M Manual
- 12 -
Faults
The Fault button is used to indicate an error has occurred. A Fault condition will stop all feeders.
The system will not restart until the Fault condition has been cleared. A Fault will also prevent the
system from starting. Up to 16 Logical Inputs and Outputs may be selected to give you a Fault
indication.
This button will remain displayed until the conditions that caused the Fault have been removed
and the Fault acknowledged. To view the Fault screen, touch
. There is an active indicator
to the left of the text (
= ON
= OFF). Any Fault that occurs will be saved until acknowledged
by you and will be displayed with a
to the left of the active indicator. If there are no Faults, this
button will be hidden from the main screens. You may still access this screen from the action
menu.
Use
and
to move the selection box to the Fault you want to acknowledge.
is used to acknowledge a Fault selected by the selection box.
is used to acknowledge
all Faults. If the error that caused an indication has not been corrected the Fault button will
continue to be displayed on the main screens and the Fault will continue to be indicated on this
screen.
Warnings
The Warning button is used to indicate a problem has occurred. Up to 16 Logical Inputs and
Outputs may be selected to give you a warning indication. A Warning condition will not stop the
system.
This button will remain displayed until the conditions that caused the Warning have been
removed and the Warning acknowledged. To view the Warning screen, touch
. There is an
active indicator to the left of the text (
= ON = OFF). Any Warning that occurs will be saved
until acknowledged by you and will be displayed with a
to the left of the active indicator. If
there are no Warnings, this button will be hidden from the main screens. You may still access
this screen from the action menu.
Use
and
to move the selection box to the Warning you want to acknowledge.
is used to acknowledge a Warning selected by the selection box.
is used to
acknowledge all Warnings. If the problem that caused an indication has not been corrected the