MC³ 90.10.EX O&M Manual
- 17 -
Flowmeter Controllers (40.10.EX). Then the Units Select (page 17) numeric parameter sets the
unit strings.
Warning:
The setting of this value incorrectly can cause erroneous calculations to be made
and may affect the operation of the system.
The next set of data that is displayed are the Max settings for each feeder. These values are
used to scale the setpoint sent to the feeder and the bar graphs on the Feeder Display screen.
Feeder Numeric
Unit Address
This number is used to identify the numeric address of the selected controller on a multi-drop line.
Controllers connected to the same communication port
cannot
have the same controller number.
Limits are minimum of 1 and a maximum of 64.
Port Number
This is the communications port that the selected feeder is attached to (0-3).
NOTE:
Two feeders may
not
have the same Port and Unit Address.
Units Select
This parameter is the index into the unit string array for the selected feeder. The 90.10.EX uses
this number to select the correct conversion factor for use when determine the setpoint.
CAUTION:
It is very important that this parameter be set to the correct value since the calculation of
the setpoint is directly affected.
Max Feedrate
This value is the Design Feedrate of the attached controller. This parameter is used to scale the
setpoint that is being sent back to the selected feeder. It is also used to scale the feedrate and
setpoint bar graphs.
CAUTION:
It is very important that this parameter be set to the correct value since the scaling of the
setpoint is directly affected.
Max Wt/Load
This parameter represents the maximum belt load or maximum hopper weight of the feeder
during normal operation. This number is used to scale the bar graph on the Feeder Display
screen.
Max Speed
This value represents the maximum speed of the belt when the unit type is set to
. If
the unit type is set to
or
, this value should be set to 100 to scale the bar
graph to the SCR output value of the selected feeder.