MC³ 90.10.EX O&M Manual
- 28 -
When done, touch return. If return is touched without touching accept the new values will not be
placed into memory.
Analog Outputs
The purpose of this section is to configure the Analog Outputs. Each analog output may be 0-
20mA (0-10V) or 4-20mA (2-10V). The type of output may be for Feedrate, the current setpoint
or available for use by commications. To change the settings for any of the outputs, just press on
the button to cycle through the choices for type and output rating. The percentage will be scaled
to the design feedrate.
Mode
The output is scaled to the design feedrate.
The output is the current setpoint scaled to the design feedrate.
This mode makes the output available for use by an external source via the
communications port.
Type
The mode selected is scaled between 0 and 20 mA (0 and-10V).
The mode selected is scaled between 4 and 20 mA (2 and 10V).
Numeric Parameters
Zero Values – The zero values are used to scale the zero point for each of the analog outputs.
This allows you to scale the zero value to the desired mA or V required for your system.
Full Values – This allows you to adjust the scaling of the output to fit you system.
Analog Output Cal
This menu allows direct access to the analog outputs. This allow verification analog lines going
to external equipment.
To use this menu, the
and
buttons adjust the selected output by 5% or 1 mA. The
output buttons,
, toggle between the adjusted value and 0 (or off).