24
e -) Error Assignment Menu :
If desired, you can program the programmable contacts for any of the following error messages.
When an error code that you have assigned to the program occurs, the DO1 and DO2 relays
check out.
SSM-6
Motors
are
equipped
with
two
programmable independent relays. You can use
DO1 (1st Relay contact output) and DO2 (2nd
Relay contact output) to provide angle value
warnings or for two separate items of information.
The connection of the relays is made as shown in
Figure 16
.
Example :
Select LSO under the DO1-FUN in the
menu, and by following the menu in
Figure 17,
you can assign a contact output at any angle
between 1° and 89°. If INP.ALM. is selected under
the DO2-FUN for the second relay, a contact can
be received from the second relay when the analog
input is interrupted.
Figure 17:
Digital relays error assignment menu
Figure 18 :
Motor angle contact info