Selectable functions in ON-OFF and TPSC Motors :
The available functions on the SSM-6 Servo motors within the two operational
modes (ON-OFF and TPSC) are as follows.
a
– Standard password entry – Creating a new password (to prevent settings from being changed)
b
– Changing the direction of the Motor to CW (Clockwise) or CCW (Counterclockwise)
c
– Minimum and maximum angle settings (Any angle between 0° and 90°)
d -
Programmable two dry contact outputs (Error assignment menu)
e –
Error assignment menu and the display of 10 retrospective errors,
f -
Manual operation feature.
Make sure the device is correctly grounded before providing power the servo
Motor! When it is necessary to change or adjust the function, it is important to pay the necessary
attention to electrical hazards to prevent loss of life!
The standard password entry in all models of Merkür motors is as in
Figure 11
.
You must know your login password in order to enter the password settings menu. The default
password on SSM-6 servo motors is 1 2 3 4. You should follow the procedure in Figure 11 to enter
the password.