3.4.6
Factory Installed Manual Gas Shutoff Valve
A manual gas shutoff valve is factory installed and located on the right side of the fireplace. Remove the slotted cover plate on
the right side of the fireplace to access the valve handle. To operate the manual gas shutoff valve, insert the tip of the gl ass
latch tool into the hole in the ball valve handle, or use your hand. Rotate the tool downward 90 -Degrees or until it stops to fully
close the Valve. To open valve, insert tool in valve bracket rotate upward 90 -degrees or until it stops.
Figure 3-31 EMERGENCY GAS SHUTOFF
3.4.7
Gas Inlet Fittings Information
Caution: Be for e you r un the gas line , r e ad, unde r stand, and pr ope r ly c alc ulate the r e quir e d gas line size .
Impr ope r (too small) gas line size applic ation c an le ad to imp r ope r bur ne r ignition and c an c ause pr ope r ty
damage and/or injur y. If you ar e not qualifie d or c e r tifie d to r un a gas line , do not pr oc e e d. Contac t a
qualifie d Gas Plumbe r .
The gas inlet fitting supplied with this Fireplace provides a 1/2
”
female NPT fitting.
This requires you to supply a ½” NPT male
fitting for connection to this appliance.
Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 1/2
” male NPT flex end
adapter.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...