85-03-01205
ML-SERIES FIREPLACE
Page
73
5.4.3
Remote Control Functions
NOTE
: You will hear an audible beep once every time a remote-control button is pressed, signaling that the command has been
received. If you do not hear the beep, press the button again.
Locate the four function buttons on the remote control:
1.
On/Off Button
: This button turns the fireplace on or off. When this button is pressed, and the system is off, the pilot will
ignite. After pilot ignition, the pilot will light the main burners. Refer to IPI and CPI Modes in this manual for pilot
ignition.
2.
Thermostat Button
: This button will allow the selection of three modes: Manual, Normal Thermostat, and Smart
Thermostat.
a.
Manual (Off)
: In this mode, the fireplace can be turned on, regardless of the room temperature. The actual room
temperature has no effect in this mode. All other functions such as fan speed control, flame height control,
secondary burner on/off control and accent light intensity controls are manually controlled.
W A RNING: Do not le ave this applianc e bur ning and unatte nde d for long pe r iods in the manual(off) mode .
L e aving the applianc e bur ning in manual (off) mode for long pe r iods c an le ad to ove r he ating of the living
spac e whic h c an ne gative ly affe c t plants, animals, infants and vulne r able pe ople .
Note : In Manual Mode , the fir e plac e will automatic ally shut off afte r 1 2 hour s of c ontinuous use . In Nor mal
The r mostat and Smar t The r mostat mode s, if the fir e plac e doe s not r e c e ive a pr ompt fr om the r e mote -
c ontr ol tr ansmitte r for 6 0 minute s, the fir e plac e will automatic ally shut off. This c an oc c ur if the r e mote
c ontr ol is move d to anothe r r oom or if the r e mote batte r ie s ar e ve r y we ak.
b.
Normal Thermostat (On)
: In this mode, the fireplace will turn
itself on and off, depending on the temperature you set.
When you set the fireplace thermostat, the fireplace will stay
functioning until the room temperature increases 1
o
F above
the set thermostat temperature. To increase the thermostat
temperature, press the up button until the desired
temperature is displayed in the thermostat temperature window. The fan will turn on five minutes after fireplace
startup and will turn off 12-1/2 minutes after the flames turn off, in this mode. The flame height can be adjusted
while the fireplace is functioning, fan speed can be adjusted after five minutes of startup. Rear burner can be turned
on or off at any time after startup. The accent light can be adjusted any time after startup.
c.
Smart Thermostat (Smart)
: In this mode, room temperature is maintained and flame height adjusts automatically to
provide continual, efficient heat. All other functions of the normal thermostat mode, except the flame height
adjustment, are allowed. Manual flame height adjustment is not allowed in this mode. The Smart Thermostat
function adjusts the flame height in accordance to the difference between the set point temperature and the actual
room temperature. As the room temperature gets closer to the set point temperature , the Smart Thermostat
automatically modulates the flame down.
3.
Up/Down Button:
This button is used to increase or decrease the thermostat temperature, flame height, fan speed, and
accent light intensity.
4.
Mode Selection Button:
This button is used to toggle between the various function icons: flame height, fan speed,
accent light.
Figure 5-1 Display Modes
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...