4.9.3
High Altitude Installation Information
Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venti ng
requirements and venting restrictions.
4.9.4
Maximum Horizontal Run
❑
Maximum Horizontal Run allowed is 32 feet if a vertical starter section that is between 4 feet to 14 feet is connected
directly to this fireplace’s flue starter collar and no more than three (3) 90
-degree elbows are used.
❑
Maximum Horizontal Run allowed is 6
” if a
18
” starter vertical section
is connected directly to this fireplace’s flue
starter collar.
4.9.5
Maximum Vent System Length
❑
Combined total length of all straight pipe sections in the vent system shall be less than 46 feet.
❑
Combined total length of all straight pipe sections in the vent system shall be less than 46 feet when using three (3) 90-
degree elbows or equivalent and terminating the vent system horizontally.
❑
Combined total length of all straight pipe sections in the vent system shall be less than 46 feet when using four (4) 90-
degree elbows or equivalent and terminating vertically.
4.9.6
How to Calculate the Vent Lengths
For calculation purposes and usage of charts in this manual, simply add the lengths of all individual straight pipe sections. For
example: if you use two 2-foot lengths and one 4-foot length, the total vent system length will be 2+2+4 = 8 feet.
4.9.7
Using 90
0
Elbows
The ML-Series Fireplace by MENDOTA allows maximum flexibility in the use of 90
o
elbows in the vent system. The length of the
first straight vertical section directly connected to the firepla
ce’s starter collar determines the maximum horizontal run and the
number of 90
0
elbows allowed for this fireplace.
For vent systems that provide a starting vertical section that is
4’
to 14
’,
you may connect up to
32’
of horizontal pipe and up to
three 90
°
elbows. For all vertical terminations, four 90
°
elbows can be used the fourth elbow must point vertically.
4.9.8
Using 90
°
Elbows When the Initial Starter Vertical Section Is Less Than 4
’
For vent systems that provide a st
arting vertical section less than 4’ the following rules apply:
A.
You must use the Master Venting Requirements Chart.
B.
A single 90° vertical-to-horizontal elbow is already calculated into the allowable maximum horizontal run. The Venting
Requirements Chart assumes that for all horizontal runs calculated, one 90
0
elbow is used within the venting system.
Note: Each additional 90° elbow reduces the maximum horizontal distance allowed by 3'.
C.
If you plan to use more than one 90
°
elbow within the vent system, first use the Venting Requirements Chart and
calculate the maximum horizontal run you are allowed based on the first vertical section connected directly to the
fireplace. From this maximum horizontal run calcula
ted, subtract 3’ for each additional 90
°
elbow you will use.
Example:
Assume you are using a 3
’
long starter vertical section. This should allow, per the Master Venting Chart, 19
’
of
horizontal run. If you want to use three 90
°
elbows, subtract 6’
for two elbows from the 19
’
maximum allowed (3
’
for each elbow after the first elbow). This yields 13
’
as the maximum horizontal run that you are allowed to install
using the 3
’
vertical starter section.
Caution:
If a vertical-to-horizontal discharge elbow or a horizontal-to-horizontal discharge elbow is enclosed within a wall, floor or
ceiling, a top air space clearance of 3" must be maintained above the entire body of the elbow.
4.9.9
Using 45-Degree Elbows
Two 45-degree elbows may be used in place of one 90-degree elbow. On 45-degree runs, one foot of diagonal pipe is equal to
8-1/2 inches horizontal run and 8-1/2 inches vertical run. Two 45-degree elbows may be connected directly to the vent starter
adapter on this fireplace to create an offset to provide the required clearances to combustible framing or sheathing materials.
Two 45-degree elbows may be connected directly to the top of this fireplace to create a horizontal offset. 32 feet maximum
horizontal run allowed with this offset configuration only if the first vertical section connected directly to the last 45 -degree
elbow is more than 4 feet to 12 feet long. For maximum allowable horizontal distances with the 45-degree offsets, see the
Master Venting Configuration Chart.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...