85-03-01205
ML-SERIES FIREPLACE
Page
12
3.1.1.3
Step 3: Final Curing Cycle
•
With the fireplace still turned on from Step 2.
•
Set the Fan Speed Control to the lowest setting Level 1.
•
If any new curing odors are detected, continue to run the fireplace with this setting until the curing odors have
diminished.
ATTENTION
: Slight odors may still be noticeable on future startups of the fireplace. These will diminish over time as the
fireplace is used.
3.1.1.4
Additional Curing Information
It is not unusual for a fireplace to require more than 10 continuous hours on high for curing odors to diminish. There are
variables that can extend or shorten the curing time such as decorative fronts, doors, facing materials and their application.
Finish materials around the fireplace are subject to high temperatures. Finishing materials used over the fireplace in the no n-
combustible zone can see temperatures around 350° F. Materials used around the fireplace must be rated for these
temperatures. Failure to use adequate materials can result in odor problems.
Please be aware that materials used around the fireplace will heat up and have the potential to cause odor issues. Adhesives,
glue, wall substrate, wall finish material, paints and polishes are common materials that if used incorrectly will cause odor
issues. Mendota is not responsible for any odor issues caused by materials used ar ound the fireplace.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...