ML-SERIES FIREPLACE
Page
59
4.9
ML39, ML47, ML54, AND ML60 DIRECT VENTING
W A RNING: Pr ope r installation of the ve nt syste m, as r e quir e d in this manual, is vital to the pe r for manc e of
this Fir e plac e . O ve r sights or failur e to c onfor m to all installation r e quir e me nts will void the applic able
war r anty.
This he ate r must be pr ope r ly c onne c te d to a ve nting syste m in ac c or danc e with the manufac tur e r 's
installation instr uc tions. O pe r ation of this he ate r whe n not c onne c te d to a pr ope r ly installe d and
maintaine d ve nting syste m c an r e sult in c ar bon monox ide (CO ) poisoning and possibly de ath.
If the ve nt syste m of this applianc e is disc onne c te d for any r e ason, the ve nt syste ms must be pr ope r ly
r e asse mble d and r e se ale d be for e this applianc e is put into use .
CAU TI ON :
Eac h installation must c onfor m to all loc al, state and national c ode s. Re fe r to the national fue l
gas c ode and loc al zoning and c ode author itie s for de tails on installation r e quir e me nts. The Me ndota
Fir e plac e s must be ve nte d to the outside in ac c or danc e with the late st e dition of the National Fue l Gas
Code . In the abse nc e of loc al c ode s, the installation must c onfor m with National Fue l Gas Code A NSI Z2 2 3 .1
(NFPA 5 4 ), or Canadian Code CA N1 -B1 4 9 or most c ur r e nt e dition, also known as NFPA 5 4 . Do not c onne c t
this Fir e plac e to a c himne y flue se r ving a se par ate solid fue l or gas -bur ning applianc e .
The ML -Se r ie s Fir e plac e must be ve nte d to the outside and must use one of the appr ove d c oax ial r igid
duc ting syste ms.
Do Not Use any silicone sealants at pipe joints. Stove gasket cements may be used
at pipe joints but is not required
.
4.9.1
Wall Thimble Information
A wall thimble is required to be installed when penetrating any combustible wall, regardless of whether the wall Is an intern al wall
or an external wall.
Wall thimbles are designed to reduce the required clearances to the exterior surfaces of the vent pipe that pass through
combustible walls. The hole size that is specified to be cut in the wall for installation of the wall thimble takes into cons ideration the
reduced clearance requirement.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...