3.2
MECHANICAL TECHNICAL REFERENCES
3.2.1
Planning the installation
This Mendota Fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier.
When planning on appliance installation, it is necessary to determine the following information before installing:
•
Where the appliance is to be installed.
•
The vent system configuration to be used.
•
Gas supply piping.
•
Electrical Wiring.
•
Framing and finishing details.
•
Hearth Protection Pad Requirements.
•
Whether accessories such as a ceiling fan are desired.
3.2.2
Selecting Appliance Location
When selecting a location for your appliance, it is important to consider the required clearances to walls.
ML39
ML47
ML54
ML60
ML72
A
MINIMUM FRAMING DEPTH
19 1/2
B
FINISHED FRAMING WIDTH
48
54
61
67
78
C
MIN. ENCLOSURE FRAMING WIDTH
56
62
69
75
86
D
MIN. ENCLOSURE FRAMING
WIDTH (CORNER INSTALL)
82 3/8
88 5/8
95 7/8
102
113
E
MIN. ENCLOSURE FRAMING
DEPTH (CORNER INSTAL)
58 1/4
62 5/8
67 7/8
72 1/8
79 3/4
F
VENT LOCATION
21
23 1/4
25 3/4
27 7/8
31 3/4
G
BACK OF ENCLOSURE TO VENT
8
WARNING
FIRE RISK- ODOR RISK
•
Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
•
Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood.
Construct chase to all clearance specifications in manual.
•
Locate and install appliance to all clearance specifications in manual.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...