7. If mounting on the front face of the Surround/Faceplate,
mount the Backup DC Power Inlet Port fitting to the
Face DC Inlet Mount Bracket. See diagram, below.
Tighten nut.
8. Lay the Surround/Faceplate in front of this appliance
with visible face down.
9. Carefully push through and break off the two adjacent
knockouts on the face or the left side return flange. The
bottom knockout is 13/32” diameter and the top small
knock out is 5/32” diameter.
10. If mounting on the left side flange, locate the small
bracket that is welded on the back of the left leg of the
Surround/Faceplate.
11. Mount the Backup DC Power Inlet Port fitting to this
bracket. The inlet end of the Port fitting must face out-
ward towards the side flange.
MOUNTING THE COVER PLATE
1. Insert the stud on the back of the cover plate
through the small knock out hole above the DC
Inlet.
2. O
btain a 5/16” box wrench. Hold the #6 lock nut
on the backside of the Basix/Faceplate behind
the small hole.
3. Hand thread the threaded stud on the cover
plate into the lock nut until it stops.
4.
Use the 5/16” box wrench to hold the nut while
you rotate the cover plate clockwise.
5. Do not tighten completely. Leave loose enough
to freely rotate the cover plate.
CONNECTING THE BACK UP DC POWER
If the AC power is interrupted during a power outage,
plug in the battery pack (supplied with this fireplace) to
the Fireplace Backup Power Inlet Port installed on Basix
Surround or Faceplate. Place battery pack away from
heat near the Inlet Port. Once AC power is restored, un-
plug and save the battery pack and harness for future
use. Leaving Battery Pack plugged in with AC power on
is acceptable.
Содержание FV44i-PF2
Страница 20: ...19...
Страница 21: ...20...
Страница 22: ...21...
Страница 23: ...22...
Страница 24: ...23...
Страница 25: ...24...
Страница 26: ...25...
Страница 27: ...26 PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A COAL BED...
Страница 33: ...32 FV 44i GAS IGNITION SYSTEM WIRING DIAGRAM...
Страница 48: ...47...
Страница 50: ...49 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...